期刊文献+

Characterization of alternating current impedance properties of biomedical electrodes

Characterization of alternating current impedance properties of biomedical electrodes
暂未订购
导出
摘要 To study the alternating current (AC) impedance properties of Ag/AgC1 electrocardiograph (ECG) electrodes, the electrode pair was gel-to-gel connected, and then the electrical potential was recorded after a safe stimulating current passes through the electrode pair, so the AC impedance data of ECG electrodes were obtained. Varying the frequency and value of stimulating current, the detailed comparison and analysis of AC impedance properties of the electrodes were performed, and the stability was further characterized by using the continuous measurement within 24 h. The experimental results show that the AC impedance values of electrodes decreased, and then slightly increased with the increase of frequency of stimulating current. The minimum AC impedance value was obtained when the frequency was changed to 10 kHz. When the stimulating current increased, the AC impedance values of electrodes showed a slight decrease, but did not change significantly. Besides, the continuous measurement results show that the impedance value presented a significant increase in the initial 30 min, and then was stabilized in the following measuring process. To study the alternating current (AC) impedance properties of Ag/AgCl electrocardiograph (ECG) electrodes, the electrode pair was gel-to-gel connected, and then the electrical potential was recorded after a safe stimulating current passes through the electrode pair, so the AC impedance data of ECG electrodes were obtained. Varying the frequency and value of stimulating current, the detailed comparison and analysis of AC impedance properties of the electrodes were performed, and the stability was further characterized by using the continuous measurement within 24 h. The experimental results show that the AC impedance values of electrodes decreased, and then slightly increased with the increase of frequency of stimulating current. The minimum AC impedance value was obtained when the frequency was changed to 10 kHz. When the stimulating current increased, the AC impedance values of electrodes showed a slight decrease, but did not change significantly. Besides, the continuous measurement results show that the impedance value presented a significant increase in the initial 30 min, and then was stabilized in the following measuring process.
出处 《Journal of Central South University》 SCIE EI CAS 2013年第5期1254-1258,共5页 中南大学学报(英文版)
基金 Project(111gpy06) supported by Fundamental Research Funds for the Central Universities,China Project(101055807) supported by the Innovative Experiment Plan for College Students of Sun Yat-sen University,China Project(KF201115) supported by the Opening Fund of Laboratory Sun Yat-sen University,China
关键词 bioelectrical impedance electrocardiograph electrodes alternating current impedance frequency properties currentproperties 交流电流 阻抗特性 电极对 生物医学 表征 连续测量 阻抗值 交流阻抗
  • 相关文献

参考文献7

二级参考文献80

共引文献189

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部