期刊文献+

辐射光致发光剂量计玻璃的制备与性能 被引量:1

Preparation and Property of Radio-Photoluminescence Dosimeter Glass
在线阅读 下载PDF
导出
摘要 采用传统的熔融冷却法制得5种不同Li/Na原子比(7:0、5:2、1:1、2:5、0:7)的辐射光致发光剂量计玻璃,研究结果揭示了玻璃性能随玻璃组成的变化规律。混合碱作用下玻璃的化学稳定性在Li/Na原子比为5:2时为最佳,本底剂量则在Li/Na原子比为2:5时为最差。用钠离子取代锂离子后,钠离子半径大于锂离子半径(rNa+>rLi+),Na—O键较Li—O键弱,使得玻璃的紫外截止边红移。玻璃中钠离子含量增加使分子量增大,密度随之增大。在337nm紫外光激发下,荧光强度随玻璃中钠离子含量的增加而增强。电子顺磁共振实验(EPR)表明,随着玻璃中钠离子含量的增加,荧光能增大时间变短。研究结果为在玻璃剂量计实际应用中选择合适的玻璃组成提供依据。 Phosphate radio-photoluminescence dosimeter glasses with five different molar ratios of Li/Na(7∶0,5∶2,1∶1,2∶5,0∶7) were prepared by conventional melt-quenching method.The effects of mixed alkali oxides on glass chemical stability and the predose of dosimeter were investigated.The best chemical stability was achieved at Li/Na molar ratio of 5∶2.However,the dosimeter has the maximal predose when the Li/Na molar ratio is 2∶5.Because of ionic radius rNa+rLi+ and chemical bond Na—OLi—O,the cut-off wavelength is red-shifted when Li2O is replaced by Na2O.The glass density increases with the increment of Na2O.Under 337 nm UV light excitation,the fluorescence intensity increases with the increment of Na2O.Electron paramagnetic resonance test indicates that the build-up time decreases with the increment of Na2O.For the application of glass dosimeter,the suitable glass composition can be chosen according to the results.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2013年第3期502-507,共6页 Atomic Energy Science and Technology
基金 国家自然科学基金资助项目(50902137)
关键词 辐射光致发光 剂量计 银掺杂 磷酸盐玻璃 radio-photoluminescence dosimeter silver doping phosphate glass
  • 相关文献

参考文献18

  • 1JEONG-EUN R, SIYONG K, KWANG-HO C, et al. Feasibility study of radio photoluminescent glass rod dosimeter postal dose intercomparison for high energy photon beam[J]. Applied Radia tion and Isotopes, 2008, 67(2): 324-328.
  • 2刘秋江,陈朝阳,范艳伟,巴维真,丛秀云,汤新强,郭旗,陆妩,朱磊.光致荧光剂量计的研究[J].核电子学与探测技术,2007,27(2):350-353. 被引量:4
  • 3SCHULMAN J, GINTHER R J, KLICK C C, et al. Dosimetry of X-rays and gamma rays by radio-photoluminescence[J]. Journal of Applied Physics, 1951, 22(12): 1 479-1 487.
  • 4YOKOTA R, NAKAJIMA S, SAKAI E. High sensitivity silver-activated phosphate glass for the simultaneous measurement of thermal neutrons, gamma-and/or beta-rays[J]. Health Physics, 1961, 5(2): 219-224.
  • 5YOKOTA R, IMAGAWA H. ESR studies of radio-photoluminescent centers in silver-activated phosphate glass[J]. Journal of Physical Society of Japan, 1965, 20:1 537-1 538.
  • 6YOKOTA R, IMAGAWA H. Radio-photolumi- nescent centers in silver-activated phosphate glass [J]. Journal of Physical Society of Japan, 1967, 23(5): 1 038-1 048.
  • 7DMITRYUK A, PARAMZINA S, SAVVINA O. Nature of radio-photoluminescence centers in silver-activated phosphate glasses[J]. Optics and Spectroscopy: English Translation, 1989, 66 (5): 1 070-1 075.
  • 8HSU S, YEH S, LIN M, et al. Comparison on characteristics of radio-photoluminescent glass dosimeters and thermoluminescent dosimeters[J]. Radiation Protection Dosimetry, 2006, 119 (1-4) : 327-331.
  • 9ZHENG W, KUROBORI T. Assignments and optical properties of X-ray induced color centers in blue and orange radio-photoluminescent silver- activated glasses[J]. Journal of Luminescence, 2011, 131(1): 36-40.
  • 10FAN S, YU C, HE D, et al. Gamma rays in- duced defect centers in phosphate glass for radio photoluminescence dosimeter [ J ]. Radiation Measurements, 2011, 46(1): 46-50.

二级参考文献64

  • 1邓再德,孙家森,印冰,杨钢锋,陈东丹.钠钡铝磷酸盐玻璃的结构与性质[J].华南理工大学学报(自然科学版),2005,33(3):5-8. 被引量:5
  • 2MOSCOVITCH M, JOHN T J S, CASSATA J R, et al. The application of LiF: Mg, Cu, P to large scale personnel dosimetry: Current status and future directions[J]. Radiat Prot Dosim, 2006, 119(1-4) : 248-254.
  • 3BEKER K. High T-dose response of recent silveractivated phosphate glasses [J ]. Health Phys, 1965, 11(6): 523-529.
  • 4PIESCH E, BURGKHARDT B, VILGIS M. Photoluminescence dosimetry-progress and state of art[J]. Radiat Prot Dosim, 1990, 33 (1-4):215-226.
  • 5OBERHOFER M,SCHARMANN A.应用热释光剂量学[M].北京:中国计量出版社,1988:118-120.
  • 6AKSELROD M S, KORTOV V S, KRAVETSKY D J, et al. Highly sensitive thermoluminescent anion-defective α-Al2O3 :C single crystal detector[J]. Radiat Prot Dosim, 1990, 32.. 15-21.
  • 7YUKIHARA E G, MITTANI J C, VANHAVERE F, et al. Development of new optically stimulated luminescence neutron dosimeters [C/OL]//15th International Conference on Solid State Dosimetry, Delft, The Netherlands, July 8-13, 2007: international solid state dosimetry organization. [2007-08-05]. http://www.ssd15.org/abstracts/2-06.doc.
  • 8YASUDA H, FUJITAKA K. Solid-state integrating detectors as an indicator of biological doses from HZE particles[J]. Advances in Space Research, 2002, 30(4): 927-932.
  • 9ARAKI F, MORIBE N, SHIMONOBU T, et al. Dosimetrie properties of radiophotoluminescent glass rod detector in high-energy photo beams from a liner accelerator and Cyber-Knife [J]. Med Phys, 2004, 31(7): 1 980-1 985.
  • 10NAKAGAWA K, YODA K, SHIRAKI M, et al. Radiophotoluminescence dosimetry using a small spherical glass: A preliminary phantom study[J]. Radiat Prot Dosim, 2007, 123 (2): 254-256.

共引文献23

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部