期刊文献+

300MW火力发电机组炉水pH值超标的原因分析 被引量:1

Cause analysis of boiler water pH value exceeding the standard limit in 300 MW coal-fired power plant
在线阅读 下载PDF
导出
摘要 针对大唐户县热电厂1号机组正常运行中,炉水pH值出现频繁超标的现象(维持10.0左右变化不大),通过试验和分析,找出炉水pH频繁超标的主要原因,并进行了处理。分析结果表明:由于高速混床树脂除去阳离子的能力减弱,导致Na+泄漏严重,为游离碱NaOH生成创造了条件,导致炉水pH值随之增大。 Aiming at the phenomenon of when normal operation frequently appearing boiler water pH value exceeding the standard limit in No. 1 Unit of Datang $haanxi Hu County Thermal Power Plant, through test and analysis, finds out the main causes of pH value frequently exceeding the standard lim- it, and makes treatment. The analysis result shows that due to the eliminating positive ion capability of high-speed mixed - bed resin weaken, leads to Na* badly leakage, which creates conditions for pro- ducing of dissociated alkali NaOH, as a result boiler water pH value be increasing.
作者 宋卫荣
出处 《宁夏电力》 2013年第1期64-66,共3页 Ningxia Electric Power
关键词 300MW火力发电机组 炉水 PH值 超标 300 MW coal-fired power plant boiler water pH value exceeding the standard limit