期刊文献+

Simplified mathematical model of inter-turn short circuit of field windings in hydro-generators and its application 被引量:5

Simplified mathematical model of inter-turn short circuit of field windings in hydro-generators and its application
原文传递
导出
摘要 Inter-turn short circuit of field windings is a common electrical fault of generators.Simulation is an important method of investigating the fault and providing data support for fault monitoring.However,huge numbers of pole pairs and damper loops in large hydro-generators would lead to lengthy calculation time,hindering scientific research and engineering application.To deal with this problem,we analyze a theoretical basis for a damper winding simplified model and then propose an equivalent treatment method.Through the analysis of steady-state current harmonic characteristics of generators with different stator winding configurations during the fault,the simplified models suitable for steady-state calculation are derived from two aspects,namely,additional rotor harmonic current frequency characteristics and the relationship of the amplitude as well as the phase of each branch current of the stator.The calculation and experimental results of the two simplified models are then compared to verify the models' correctness.A calculation example of the Three Gorges left bank VGS generator shows few deviations between the calculation results of the simplified model and the original model.Moreover,the calculation time using the simplified model is 1/1500 that using the original model,which provides a more effective tool for on-line fault monitoring.Finally,the sensitivity-verification application of the fault-monitoring scheme based on the stator steady-state unbalanced current RMS is depicted.The result shows that the scheme can monitor two-turn short circuits of field windings in the Three Gorges generator and provide high sensitivity.
出处 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第4期898-909,共12页 中国科学(技术科学英文版)
基金 supported by the National Natural Science Foundation of China (Grant No. 50807027) the China Postdoctoral Science Foundation(Grant No. 2012M520155) the Fundamental Research Funds for the Central Universities (Grant No. 2013JBM081)
关键词 HYDRO-GENERATOR field windings inter-turn short circuit simplified model on-line monitoring 水轮发电机 数学模型 励磁绕组 匝间短路 应用程序 计算时间 电气故障 VGS发电机
  • 相关文献

参考文献6

二级参考文献44

  • 1王维俭,刘俊宏,蒙宁海.大型水轮发电机不完全差动保护的分析计算[J].中国电机工程学报,1994,14(3):42-47. 被引量:5
  • 2诸嘉慧,袁新枚,邱阿瑞,王维俭,刘志强,郭玉恒.大型水轮发电机转子偏心对单元件横差保护影响的分析[J].电力系统自动化,2005,29(11):45-48. 被引量:11
  • 3吴新振,王祥珩,罗成.多相异步电机谐波电流与谐波磁势的对应关系[J].清华大学学报(自然科学版),2005,45(7):865-868. 被引量:38
  • 4桂林,王祥珩,孙宇光,王维俭.大型汽轮发电机新型中性点引出方式的研究[J].电力系统自动化,2006,30(1):56-59. 被引量:9
  • 5高景德 王祥珩.交流电机的多回路理论[J].清华大学学报,1987,(1).
  • 6KRYUKHIN S S. A new principle for synchronous machine protection from rotor winding inter turn and double earth faults [J]. Electric Technology USSR, 1972, 2(5): 47-59.
  • 7MUHLHAUS J, WARD D M, LODEGE I. The detection of shorted turns in generator rotor windings by measurement of circulating stator currents [C]// Proceedings of the 2nd International Conference on Electrical Machines-design and Aoolications, September 17-19, 1985, London, UK: 100-103.
  • 8TORLAY J E, CORENWINDER C. Analysis of shaft voltages in large synchronous generators [C]// Proceedings of 1999 International Conference on Electric Machines and Drives, May 9-12, 1999, Seattle, WA, USA: 607-609.
  • 9WANG Xiangheng, CHEN Songlin, WANG Weijian, et al. A study of armature winding internal faults for turbo generators [J]. IEEE Trans on Industry Applications, 2002, 38 (3): 625-631.
  • 10KRYUKHIN S S. A new principle for synchronous machine protection from rotor winding inter-turn and double earth faults [J]. Electrical Technology, 1972, 2(5): 47-59.