低剂量CT扫描获取颌面部软硬组织三维模型的初步研究 被引量:4

A preliminary study of the application of low-dose CT in the construction of 3D model of maxillofacial hard and soft tissues
暂未订购
导出
摘要 目的:评价低剂量CT扫描获取颌面部软硬组织三维模型的可行性,为低剂量CT在颜面赝复体计算机辅助设计制作中的应用提供研究依据。方法:征集20例需要接受颌面部CT检查的患者,分别进行常规剂量(280 mAs)和低剂量(35 mAs)CT扫描,记录扫描时容积剂量指数(CTDIvol)和剂量长度乘积(DLP);应用Mimics 10.01软件重建软硬组织三维模型;利用Geomagic 11.0软件进行三维比较,评价不同扫描剂量下重建软硬组织三维模型表面形态的差异。结果:常规剂量和低剂量扫描条件下,2组间CTDIvol值和DLP值的差异均具有统计学意义(P<0.05);软硬组织三维模型配准后3D比较生成彩虹图显示其表面形态的差异不大于0.5 mm,软硬组织三维模型对应各标记点坐标值无统计学差异(P>0.05)。结论:低剂量(35mAs)CT扫描可用于获取颌面部软硬组织的三维模型。 Objective: To study the feasibility of low-dose CT (LDCT) in the construction of three-dimensional (3D) model of the maxillofacial hard and soft tissues. Methods: The craniofacial CT examination was conducted by conventional dose(280 mAs) and low dose (35 mAs) in 20 patients, the scanning volume CT dose index (CTDIvol) and dose-length product(DLP) were recorded. The 3D model of the hard and soft tissues were reconstructed with Mimics 10.01 software, and 3D comparison of the morphologic data between LDCT and conventional dose CT was carried out with Geomagic 11.0 software. Results: There was statistical significance(P 〈0.05)in CTDIvol and DLP values, rainbow diagram generated by 3D comparison of the models of the hard and soft tissues showed that the differ- ences of the surface morphology was not greater than 0.5 mm, there was no statistical significance ( P 〉 0.05 ) in coordinate values (X, Y and Z values) of each corresponding marked points of the hard and soft tissues. Conclusion: The low-dose (35 mAs) CT can be used to obtain three-dimensional model of the maxillofacial hard and soft tissues.
出处 《实用口腔医学杂志》 CAS CSCD 北大核心 2013年第2期214-218,共5页 Journal of Practical Stomatology
基金 国家自然科学基金(编号:81271188) 陕西省自然科学基金(编号:2012JQ4004)
关键词 CT 低剂量 三维模型 赝复体 CT Low- dose Three- dimensional model Prosthesis
  • 相关文献

参考文献6

  • 1Naidich DP, Marshall CH, Gribbin C, et al. Low-dose CT of the lungs: Preliminary observations [ J ]. Radiology, 1990, 175(3) :729 -731.
  • 2高倩,赵铱民,白石柱,吴国锋,王博.正常人外鼻缺损种植区域三维测量[J].实用口腔医学杂志,2010,26(2):198-201. 被引量:2
  • 3Watanabe H, Honda E, Tetsumura A, et al. A comparative study for spatial resolution and subjective image characteris- tics of a multi-slice CT and a cone-beam CT for dental use [J]. Eur J Radiol, 2011,77(3) :397 -402.
  • 4Sohaib SA, Peppercorn PD, Horrocks JA, et al. The effect of decreasing mAs on image quality and patient dose in sinus CT[J]. Br J Radiol, 2001,74(878):157- 161.
  • 5付传明,王开华,陈义加,陈伦刚,龚晓虹,陈文,熊寅,吴文强.低剂量CT在颅脑-颌面部外伤联合扫描中的应用[J].临床放射学杂志,2010,29(4):535-538. 被引量:9
  • 6Olszewski R, Frison L, Wisniewski M, et al. Reproducibili- ty of three-dimensional cephalometric landmarks in cone- beam and low-dose computed tomography[ J]. Clin Oral ln- vestig, 2013, 17( 1 ) :285 -292.

二级参考文献18

  • 1周洪,杨壮群.CT重建三维图像的测量与直接测量的比较[J].中华整形烧伤外科杂志,1996,12(5):379-380. 被引量:11
  • 2田志梁,雷子乔,韩萍,郑金龙,刘芳,肖杰.16层螺旋CT扫描及其图像重组技术在头面部外伤中的应用[J].临床放射学杂志,2007,26(2):182-184. 被引量:19
  • 3Nishimura RD,Roumanas E,Moy PK,et al.Nasal defects and osseointegrated implants:UCLA experience[J].J Prosthet Dent,1996,76(6):597-602.
  • 4Pare1 SM.Diminishing dependence on adhesive for retention of facial prostheses[J].J Prosthet Dent,1980,43(5):552-560.
  • 5Pare1 SM,Branemark PI,Tjellstrom A,et al.Osseointegration in maxillofacial prosthetics.Part II:Extraoral applications[J].J Prosthet Dent,1986,55(5):600-606.
  • 6Roumanas ED,Freymiller EG,Chang TL,et al.Implant-retained prostheses for facial defects:An up to 14-year follow-up report on the survival rates of implants at UCLA[J].Int J Prosthodont,2002,15(4):325-332.
  • 7Klein M,Menneking H,Neumann K,et al.Computed tomographic study of bone availability for facial prosthesis-bearing endosteal implants[J].Int J Oral Maxillofac Surg,1997,26(4):268-271.
  • 8Karakoca S,Aydin C,Yilmaz H,et al.Survival rates and periimplant soft tissue evaluation of extraoral implants over a mean follow-up period of three years[J].J Prosthet Dent,2008,100(6):458-464.
  • 9Berrington de Gonzalez A, Darby S. Risk of cancer form dlangnostic X-rays :estimatesfor the UK and 14 other countries. Lancet, 2004, 363:345.
  • 10The ALARA (as low as reasonably achievable) concept in pediatric CT intelligent dose reduction:muhidisciplinary conference organized by the Society of Pediatric Radiology. Augustls 19,2001. Pediatr Patdiol ,2002,32:217.

共引文献9

同被引文献65

引证文献4

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部