摘要 目的研究平板接种法监测牙科综合治疗台水路(DUWLs)菌落总数的可行性。方法采集某院DU-WLs系统50份水样标本,分别采用平板接种法和国家生活饮用水标准检验方法中规定的倾注平板法进行培养,比较两种方法的检测结果。结果倾注培养法和平板接种法检测DUWLs中菌落计数,差异无统计学意义(T=315.50,P>0.05);检测菌落数的合格率分别为58.00%和52.00%,差异亦无统计学意义(χ2=0.57,P>0.05)。结论平板接种法与国标倾注平板法检测DUWLs系统中的菌落总数无差异。平板接种法操作简单,易于细菌的初步鉴定,日常水质监测中可替代国标倾注平板法。 Objective To study the feasibility of plate-streaking method in monitoring total bacteria counts in dental unit waterlines (DUWLs). Methods 50 water samples from DUWLs were taken and cultured by plate streaking method and poured-plate method, colony counts of two cultured methods was compared. Results The difference in colony counts of DUWLs between poure&plate method and plate-streaking method was not significant (T= 315.50,P〉0. 05) ; the qualified rate of water was 58. 00% and 52. 00% respectively, there was no statistical difference in the qualified rate of water detected between two methods X^22 = 0. 57,P〉0. 05). Conclusion The total colony counts detected by plate-streaking method and poured-plate method is not different, plate-streaking method is easy to be performed, it can instead poured-plate method to monitor the colony counts in DUWLs.
出处 《中国感染控制杂志》 CAS 2013年第1期16-18,23,共4页 Chinese Journal of Infection Control
关键词 平板接种法 倾注平板法 牙科综合治疗台水路 菌落数 医院感染 水质监测 plate-streaking method poured-plate method dental unit waterline colony count healthcare-associ-ated infection water quality monitoring
  • 相关文献

参考文献11

  • 1伊大海,王炳华,冯言,卢爱工.《医疗机构口腔诊疗器械消毒技术操作规范》解读[J].中国实用医药,2007,2(6):119-120. 被引量:9
  • 2李罡,周学东,胡涛.水源在牙科医源性交叉感染中的作用[J].牙体牙髓牙周病学杂志,2002,12(7):393-396. 被引量:18
  • 3中华人民共和国卫生部,国家标准化管理委员会.GB/T5750.12-2006生活饮用水卫生标准生活饮用水标准检验方法[S].北京,2006:1-13.
  • 4金爱琼,常香远,宁克勤,孙墅.牙科水道细菌污染状况的调查研究[J].上海护理,2007,7(5):19-21. 被引量:2
  • 5Berger P, Glick E, Hurr P, etal. Manual for the certification of laboratories analyzing drinking water-criteria and procedures quality assurance[M]. 15th ed. Ohio:US EPA, Office of Wa- ter, 2005:87- 104.
  • 6No author. Dental unit waterlines: approaching the year 2000. ADA Council on Scientific Affairs [J]. J Am Dent Assoc, 1999,130(11) : 1653 - 1664.
  • 7Reasoner D J, Geldreich E E. A new medium for the enumera- tion and subculture bacteria from potable water[J]. Appl En- viron Microbiol, 1985,49(1) : 1 - 7.
  • 8Karpay R I, Plamondon T J, Mills S E, et al. Validation of an in-office dental unit water monitoring technique[J]. J Am Dent Assoc, 1998, 129(2) :207 - 211.
  • 9Smith R S, Pineiro S A, Singh R, etal. Discrepancies in bacte- rial recovery from dental unit samples on R2A medium and a commercial sampling device[J]. Curt Microhiol, 2004, 48(4) : 243 - 246.
  • 10吴慧清,李程思,张菊梅,吴清平.ATP生物发光法饮用水中细菌总数快速测定方法研究[J].中国卫生检验杂志,2009,19(9):1975-1978. 被引量:24

二级参考文献32

  • 1卫生部卫生法制与监督司.消毒技术规范[S].北京:中华人民共和国卫生部,2002.21~23.
  • 2GB8537-2008.饮用天然矿泉水卫生标准[S].
  • 3GB/T8538-2008.饮用天然矿泉水检验方法[S].
  • 4GB5750.1-5750.13-2006.生活饮用水卫生标准生活饮用水标准检验方法[S].
  • 5Sharon R Ford, Franklin R Leach. hnprovements in the application of firefly lueiferase assays. Methods in Molecular Biology Volume 102( Bioluminescence Methods and Protocols), 1998 : 1 - 20.
  • 6Satyanarayanan Seshadri,Taewon Han,Vahtis Krumins,et al. Application of ATP bioluminescence method to characterize performance of bioaerosol sampling devices[J]. Aerosol Sci,2009,40:113 -121.
  • 7[1]Shearer BG. Biofilm and the dental office [J]. JADA, 1996,127(2):181
  • 8[2]Blake GC. The incidence and control of bacterial infection of dental units and ultrasonic scaler [J]. Br Dent J,1963,115:413
  • 9[3]Williams HN, Paszhl-Kolva C, Shahamat M, et al. Molecular technique reveal high prevalence of Legionella in dental units [J]. JADA,1996,127(8):1188
  • 10[4]Fayle SA, Pollard MA. Decontamination of dental unit water systems: a review of current recommendations [J]. Br Dent J, 1996,181:369

共引文献60

同被引文献35

  • 1雷建华,郝梅,范永峰,崔巧珍,王丽芳.口腔科综合治疗机供水系统细菌学监测与消毒剂应用的研究[J].护理研究(上旬版),2006,20(8):2014-2015. 被引量:8
  • 2Saund D,Dietrich T.Minimally-invasive tooth extraction:doorknobs and strings revisited[J].Dent Update,2013,40(4):325-330.
  • 3Rahnama M,Czupkao L,Czajkowski L,et al.The use of piezosurgery as an alternative method of minimally invasivesurgery in the authors[J].Wideochir Inne Tech Malo Inwazyjne,2013,8(4):321-326.
  • 4Sitkowska J,Szymanska J.Bacterial contamination of dental unit waterlines[J].Environ Monit Assess,2013,18(5):3603-3611.
  • 5Arvand M,Hack Microbial A.Microbial contamination of dental unit waterlines in dental practices in Hesse,Germany:a cross-section study[J]Eur J Microbiol Immunol,2013,7(1):49-52.
  • 6Porteous N,Luo J,Hererra M,et al.Growth and identification of Bacteria in N-Halamine Dental Unit Waterline Tubing Using an Ultrapure Water Source[J].Int J Microbiol,2011,15(9):21-27.
  • 7Petti S,Moroni C,Messano GA,et al.Detection of oral streptococci in dental unit water lines after therapy with air turbine handpiece:biological fluid retraction more frequent than expected[J].Future Microbiol,2013,8(3):413-421.
  • 8Toomarian L,Rikhtegaran S,Sadighi M,et al.Contamination of dental unit water and air outlets following use of clean head system and conventional handpieces[J].J Dent Res Dent Clin Dent Prospects,2007,10(6):43-47.
  • 9Liaje A,Ozkan YK,Ozkan Y,et al.Stability and marginal bone loss with three types of early loaded implants during the first 2012 after loading[J].Int J Oral Maxillofac Implants,2012,27(1):162-172.
  • 10Smith A,Smith G,Lappin DF,et al.Dental handpiece contamination:a proteomics and surface analysis approach[J].Biofouling,2014,30(1):29-39.

引证文献4

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部