期刊文献+

初始通量对次毫米过滤组件分区高浓度污泥的影响

Effect of initial flux on sub-millifiltration module of high concentration sludge space division
原文传递
导出
摘要 以人工配制模拟中浓度生活污水为研究对象,采用自主研制的次毫米过滤组件(sub-millifiltration module,SMFM),考察了初始通量在不同孔径条件下SMFM的过滤效果。实验结果表明,起始通量越大,SMFM在运行过程中通量衰减得越快,而起始通量越小,衰减速度较慢,综合考虑出水SS满足分区要求和运行周期内通量较大2个因素,筛选出各孔径SMFM的最佳起始通量为450 L/(m2.h),运行周期为20~25 min。 Abstract Using a homemade sub-millifiltration module, the filtration effect of SMF module at the different initial flux was studied. The results showed that the flux of SMFM faded down quickly at higher flux during the operation, while the flux of SMFM faded down slowly. According to the sludge space division and the higher flux, the optimum flux of SMFM was 450 L/( m2 · h) and the periodicity of operation was 20 25 min.
出处 《环境工程学报》 CAS CSCD 北大核心 2013年第3期853-856,共4页 Chinese Journal of Environmental Engineering
基金 国家"水体污染控制与治理"科技重大专项(2009ZX07210-001-001)
关键词 初始通量 次毫米过滤组件 高浓度污泥 initial flux sub-millifiltration module high concentration sludge
  • 相关文献

参考文献9

  • 1Fuchs W. , Resch C. , Kernstock M. ,et al. Influence of operational conditions on the performance of a mesh filter activated sludge process. Water Res. , 2005, 39 ( 5 ) : 803 -810.
  • 2Alavi M. R. ,Satoh H. Performance of coarse pore filtration activated sludge system. Water Science and Technology, 2002,46 ( 11-12 ) : 71-76.
  • 3范彬,黄霞,文湘华,于妍.微网生物动态膜过滤性能的研究[J].环境科学,2003,24(1):91-97. 被引量:46
  • 4范彬,黄霞,文湘华,于妍.动态膜-生物反应器对城市污水的处理[J].环境科学,2002,23(6):51-56. 被引量:77
  • 5邱宪锋,张建,高宝玉,张成禄,陈欢.内循环动态膜生物反应器处理生活污水[J].中国环境科学,2007,27(2):165-168. 被引量:21
  • 6Kiso Y. , Jung Y. J. , Ichinari T. , et al. Wastewater treat- ment performance of a filtration bio-reactor equipped with a mesh as a filter material. Water Res. , 2000, 34 ( 17 ) : 4143-4150.
  • 7Seo G. T. ,Moom B. H. ,LeeT. S. ,etal. Non-wovenfab- ric filter separation activated sludge reactor for domestic wastewater reclamation. Water Science and Technology, 2003,47 (1) : 133-138.
  • 8M. R. Alavi Moghaddam,Satoch H. , Mino T. Effect of im- portant operational parameters on performance of coarse pore flitration activated sludge process. Water Science and Technology, 2002,46 ( 9 ) : 229-236.
  • 9高松,周增炎,高廷耀.自组生物动态膜在污泥截留中的应用研究[J].净水技术,2005,24(1):14-17. 被引量:22

二级参考文献25

  • 1薛艳,黄勇,潘杨.废水生物脱氮除磷工艺的进展与评述[J].工业用水与废水,2006,37(3):11-15. 被引量:13
  • 2国家环保局.水和废水监测分析方法(第三版)[M].北京:中国环境科学出版社,1989.108,354.
  • 3A. E. Mareinkowsky, K. A. Philips, H. O. Johnson and J. S. Shon,Hyperfiltration studies(IV) salt rejection by dynamically formed hydrous oxide membrane[J]. J. Am. Chem. Sod, 1996(88) :5744.
  • 4G. Spencer and R. Thomas, Fouling, cleaning and rejuvenation of formed-in-place membranes[J]. Food Technology, 1991 (45): 98-99.
  • 5M. R. Alavi Moghaddam, H. Satoh, etc. , Effect of important operational parameters on performance of coarse pore filtration activated sludge process[J]. Water Sei. Tech. ,2002,46(9):229-266.
  • 6Yoshiaki. Kiso. , Yong-Jun Jung. etc. , Waste water treatment performance of a filtration bio-reactor equipped with a mesh as afilter material[J]. Water Res,2000,34, (17) :4143-4150.
  • 7Bin Fan, Xia Huang. Characteristics of a Self-Forming Dynamic Membrane Coupled with a Bioreactor for Municipal Wastewater Treatment, [J] Environ. Sci. Technol, 2002,36: 5245-5251.
  • 8G. T. Seo, B. H. Moon, etc. , Non-woven fabric filter separation activated sludge reactor for domestic wastewater reclamation[J].Water Sei. Tech. ,2003,47(1) :133-138.
  • 9国家环保局《水和废水检测分析方法》编委会.水和废水检测分析方法(第3版)[M].北京:中国环境科学出版社,1989..
  • 10Bouhabila El H, Aim R G, Buisson H. Fouling characteriza tion in membrane bioreactors. Sep. Purif. Technol., 2001,22~23: 123~132.

共引文献111

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部