摘要 研究了在陶瓷管载体内壁制成高岭土动态膜及动态膜对城市二级出水的过滤性能、动态膜的清洗和再生方法.实验中采用错流操作方式处理二级出冰.结果表明,涂膜液中高岭土质量浓度在0.3~0.7 g/L、涂制时间在10~37 min时,成膜的水处理性能差别不大;跨膜压差对过滤有一定影响,当0.1~0.3 MPa时,滤出液通量基本相同,但明显低于0.4 MPa时滤出液通量;错流速度对过滤影响显著,速度愈大则滤出液通量愈大,错流速度在1~2 m/s时出水通量比较稳定.动态膜对浊度的去除率基本上为100%,对COD(化学需氧量)去除率约为40%. The performances of kaolin dynamic membrane, formed on the inner wall of a ceramic tube for the filtration of secondary effluent from domestic wastewater treatment plant are studied, and its cleaning and regeneration methods are investingated. It shows that the membrane gives almost the same characters when the concentration of kaolin is between 0.3 to 0.7 g/L, and the deposit time between 10 to 37 minutes. The transmembrane pressure and especially the crossflow velocity have important effects on the filtration processes, Dynamic membrane can be used effectively with turbidity removal rate nearly 100%, and COD removal rate about 40%, Cleaning and regeneration of the dynamic membrane are very convenient if necessary.
出处 《上海理工大学学报》 EI CAS 北大核心 2005年第4期323-326,共4页 Journal of University of Shanghai For Science and Technology
基金 上海市科委重点科技攻关项目(012312032)
关键词 高岭土 动态膜 错流过滤 二级出水 kaolin dynamic membrane cross flow filtration secondary effluent
  • 相关文献

参考文献5

  • 1Cai Bang-xiao, Ye Hai-lin, Li Yu. Preparation and separation performance of a dynamically formed MnO2 membrane[J]. Desalination, 2000,128: 247~256.
  • 2Galjaard G, Buijs P, Beerendonk E, et al. Pre-coating (EPCE(R)) UF membranes for direct treatment of surface water[J]. Desalination, 2001,139: 305~316.
  • 3Wang Juh-yaun,Liu Ming-chyi. Formation of dextran-Zr dynamic membrane and study on concentration of protein hemoglobin solution [J]. Journal of Membrane Science,1999,162:45~55.
  • 4Li Na, Liu Zhong-zhou,Xu Shu-guang. Dynamically formed poly (vinyl alcohol) ultrafiltrationmembranes with good anti -fouling characteristics[J]. Journal of Membrane Science,2000,169:17~28.
  • 5范彬,黄霞,文湘华,于妍.微网生物动态膜过滤性能的研究[J].环境科学,2003,24(1):91-97. 被引量:46

二级参考文献7

  • 1国家环保局.水和废水监测分析方法(第三版)[M].北京:中国环境科学出版社,1989.108,354.
  • 2Bouhabila El H, Aim R G, Buisson H. Fouling characteriza tion in membrane bioreactors. Sep. Purif. Technol., 2001,22~23: 123~132.
  • 3Barker D J, Stucky D C. A review of soluble microbial products (SMP) in wastewater treatment systems. Wat. Res. ,1999, 33(14): 3063~3082.
  • 4Wisniewski C, Grasmick A . Floc size distribution in a membrane bioreactor and consequences for membrane fouling.Colloid. Surf., 1998, 138: 403~411.
  • 5Nagoka H, Ueda S, Miya A. Influence of bacterial extracellular polymers on the membrane separation activated sludge process. Wat. Sci. Technol. , 1996, 34(9): 165~172.
  • 6Lee J, Ahn W-J, Lee C-H. Comparison of the filtration characteristics between attached and suspended growth microorganisms in submerged membrane bioreactor. Wat.Res., 2001, 35(10): 2435~2445.
  • 7范彬,黄霞,文湘华,于妍.动态膜-生物反应器对城市污水的处理[J].环境科学,2002,23(6):51-56. 被引量:77

共引文献45

同被引文献175

引证文献11

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部