摘要
分析了变频牵引电机绞线对经热老化、电老化及电热联合老化后的3条介损-电压曲线(tanδ-U曲线),与其在高温下的tanδ-U曲线进行对比,并比较了绞线对在不同老化程度下的tanδ-U曲线。结果表明:绞线对经热老化及电热联合老化后测得的第1条tanδ-U曲线的转折点对应的电压明显比后2条tanδ-U曲线的高;经验证该转折电压为绞线对的局部放电起始放电电压(PDIV);随着老化程度的加深,测得的第1条tanδ-U曲线的转折点电压增大。
Three dielectric loss-voltage(tanδ-U) curves of inverter-fed traction motor twisted pair after expe-riencing thermal aging, electrical aging and electrical-thermal aging were tested separately; and then com-pared with the tanδ-U curve tested under high temperature. The tanδ-U curves of the twisted pair under different aging degrees were also tested. The results show that the corresponding voltage of turning point in the first tanδ-U curve is obvious larger than that of the latter two tanδ-U curves of the twisted pairs after thermal aging and electrical-thermal aging. It is verified that the corresponding voltage of turning point is the partial discharge inception voltage(PDIV) of the twisted pair. With the deepening of the ag-ing degree, the corresponding voltage of turning point in the first tanδ-U curve increases.
出处
《绝缘材料》
CAS
北大核心
2013年第1期45-48,共4页
Insulating Materials
基金
国家自然科学基金(51177136)
关键词
变频牵引电机
绞线对
老化
介质损耗
局部放电
inverter-fed traction motor
twisted pair
aging
dielectric loss
partial discharge