分析了引起变频电机绝缘材料过早失效的主要因素,介绍了变频电机绝缘材料寿命评估检测设备的主要参数,提出标准定义中脉冲上升时间存在的问题,给出了脉冲电压上升率指标,指出在用示波器测试上升时间时应注意的问题,最后介绍了变频电机绝缘材料的寿命评估方法。
The main factors causing premature failure of insulating materials for inverter-fed motor were analyzed and the main parameters of life assessment testing equipment were stated.The problems in standard definition for pulse rise time were put forward and the pulse voltage rise rate index was given.The problems in using oscilloscope to test the rise time were pointed out and finally,the life assessment methods of inverter-fed motor insulating materials were presented.
出处
《绝缘材料》
CAS
北大核心
2011年第5期55-58,共4页
Insulating Materials
基金
广西自然科学基金项目(2011GXNSFA018022)
桂林电器科学研究院产学研项目(09501)
桂林电器科学研究院青年创新基金项目(10522)
关键词
变频电机绝缘
耐电晕
寿命评估
脉冲电压上升率
inverter-fed motor insulation
corona-resistance
life assessment
pulse voltage rise rate