期刊文献+

超声多普勒成像中接收信号的分离方法研究 被引量:2

Separation of Return Signals in Ultrasound Doppler Imaging
暂未订购
导出
摘要 超声多普勒成像被广泛应用于血流速度测量及人体循环系统的诊断分析。为了从超声回波信号中提取有价值的血流多普勒信号,分析了血流反射信号、血管壁散射信号和其他一些噪声信号的各种性质及分布特点,应用基于时频、子空间分离等信号分离方法,解决了超声成像中广泛存在的非有用信号的去除问题,较之简单的壁滤波处理,更具优越性,从而有利于后续信号处理及最终成像结果。 Ultrasound Doppler imaging is widely used in measuring the velocity of blood and diagnosis of human circulation system. To extract Doppler blood signal from wall clutter and other noise signal, these signals' nature and statistical characteristics are investigated and compared. Nonlinear filtering method based on time-frequency and subspace are used for de-noising and removing other disturbing signals, which facilitates a high accuracy and reliability of the further parameter extraction and signal analysis.
出处 《医疗卫生装备》 CAS 2012年第12期87-89,共3页 Chinese Medical Equipment Journal
基金 川北医学院高教教改项目(11-06-074)
关键词 超声多普勒 声像图 信号处理 模式识别 ultrasound Doppler sonography signal processing pattern recognition
  • 相关文献

参考文献24

  • 1万明习;宗瑜瑾;王素品.生物医学超声学[M]北京:科学出版社,2010.
  • 2Shung K K. Diagnostic Ultrasound:imaging and blood flow measurements[M].Boca Raton:crc Press,2006.
  • 3Bushburg J T,Seibert J A,Leidholdt E M. The essential physics for medical imaging[M].Philadelphia:Lippincott Williams and Wilkins,2002.
  • 4王威琪,汪源源.医学超声信号及其特征提取[J].中国医疗器械信息,2004,10(1):4-11. 被引量:6
  • 5金大伟,汪源源,陶倩,张羽,王威琪.血流与管壁超声多普勒信号分离方法的实现与比较[J].声学技术,2007,26(1):27-31. 被引量:2
  • 6张榆锋,丁坤,章克信,余琦,陈三生.超声多普勒管壁搏动和血流信号的分离研究[J].中国生物医学工程学报,2007,26(5):641-646. 被引量:3
  • 7Gronningsaeter A,Angelsen B A J,Hans G Torp. Blood noise reduction in intravascular ultrasound imaging[J].IEEE transactions on Ultrasound Ferroelectrics and Frequency control,1995,(02):200-209.doi:10.1109/58.365234.
  • 8王沛东,沈毅,王艳.超声彩色血流成像中非平稳杂波的抑制[J].中国生物医学工程学报,2008,27(2):240-243. 被引量:3
  • 9Ford M D,Alperin N,Lee S H. Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries[J].Physiological Measurement,2005.477-488.
  • 10Gronningsaeter A,Angelsen B A J,Hans G Torp. Blood noise reduction in intravascular ultrasound imaging[J].IEEE transactions on Ultrasound Ferroelectrics and Frequency control,1995,(02):200-209.doi:10.1109/58.365234.

二级参考文献101

共引文献33

同被引文献42

  • 1彭京思,彭虎.基于正弦调频连续波的超声多普勒血流速度的测量[J].生物医学工程研究,2012,31(2):70-73. 被引量:2
  • 2邓建奇,刘东权,周激流.一种实时超声血流速度的估算与显示方法[J].生物医学工程学杂志,2007,24(3):530-533. 被引量:5
  • 3Gudmundson E, Jakobson A, Jensen JA, et al. Blood velocity estimation using ultrasound and spectral iterative adaptive approaches[J]. Sign Process, 2011 (91): 1275-1283.
  • 4Kunita M, Sudo M, Inoue S, et al. A new method for blood velocity measurement using ultrasound FMCW signals[J]. IEEE Trans Ultrason Ferroelectr Freq Contr, 2010, 57(5): 1064-1076.
  • 5Jensen J A, Nikolov SI, Udesen J, et al. Recent advances in blood flow vector velocity imaging[C]. IEEE Int Ultrason Symp, 2011: 262-271.
  • 6Dunmire B, Beach KW. Brief history of vector Doppler[C]. Proc SPIE, 2001: 200-214.
  • 7Swillens A, Segers P, Torp H, et al. Two-dimensional blood velocity estimation with ultrasound speckle tracking versus crossed-beam vector Doppler based on flow simulations in a carotid bifurcation model[J]. 1EEE Trans Ultrason Ferroelectr Freq Contr 2010, 57(2): 327-339.
  • 8Eranki A, Almuhanna K, Siddhartha S. Characterization of a vector Doppler system based on an array transducer[C]. IEEE lnt Ultrason Syrup, 2010: 1076-1079.
  • 9Marion A, Aoudi W, Basarab A, et al. A comparative study of [bur vector velocity estimation methods applied to flow imaging[J]. Phys Proced, 2010(3): 225-233.
  • 10Hui L, Liu DC. Blood flow velocity estimation from ultrasound speckle tracking using chirp signals[C]. 3rd Int Conf Bioinfbrm Biomed Eng, 2009: 1-4.

引证文献2

二级引证文献14