期刊文献+

利用射频信号解卷积估计组织和血流运动速度 被引量:1

Estimation of velocities of tissue motion and blood flow based on radio frequency signal deconvolution
暂未订购
导出
摘要 基于射频信号解卷积,提出了一种无需MTI(Moving Target Indicator)滤波重建血流及组织运动速度的方法。对射频回波的采样序列进行快速傅里叶变换,在频域对相邻两次射频回波的频谱作解卷积处理,通过分析解卷后的数值序列得到组织和血流各自的运动速度。仿真实验对两组典型的时延参数的超声回波信号进行了血流和组织速度的估算,并与给定值比较,证明了方法的有效。该方法有助提高超声血流成像系统对低速血流的测量精度。 A novel approach based on radio frequency signal deconvolution is developed to estimating the velocities of blood flow and tissue motion without MTI filtering.In this method,the sampled sequences of the radio frequency echoes are transformed to the frequency domain by FFT algorithm firstly.Then these transformed sequences are deconvolved.Finally the velocities of the blood flow and the tissue motion can be obtained by a spectrum analysis of these deconvolved sequences.This approach has been applied to the simulated ultrasound echoes with two typical time-delay parameter sets.The validity of this method is examined by the comparison between the estimated velocities of blood and tissue motion and the given values.This approach is helpful to the measurement of the low-velocity blood flows.
出处 《声学技术》 CSCD 2010年第2期171-175,共5页 Technical Acoustics
基金 教育部新世纪人才计划资助项目(06-0450)
关键词 彩色血流估计 解卷积 时延估计 杂波抑制 color flow estimation deconvolution time delay estimation clutter rejection
  • 相关文献

参考文献11

  • 1Moehring M A,Spencer M P.Power m-mode Doppler (PMD) for observing cerebral blood flow and tracking emboli[J].Ultrasound Med Biol,2002,28(1):49-57.
  • 2Oddershede N,Lovstakken L,Torp H,Jensen J A.Estimating 2-D vector velocities using multidimensional spectrum analysis[J].2008,55(8):1744-1754.
  • 3汪源源,张羽,周国辉,余建国,王威琪.多普勒血流信号最大频率曲线的特征分析及应用[J].声学技术,2001,20(3):97-99. 被引量:1
  • 4金大伟,汪源源,陶倩,张羽,王威琪.血流与管壁超声多普勒信号分离方法的实现与比较[J].声学技术,2007,26(1):27-31. 被引量:2
  • 5Bjerum S,Torp H,Kristoffersen K.Clutter filters adapted to tissue motion in ultrasound color flow imaging[J].IEEE Trans Ultrason.Ferroelec.Freq.Contr,2002,49(6):693-704.
  • 6金大伟,汪源源,王威琪.空间选择性降噪法提取血流超声多普勒信号[J].声学学报,2007,32(3):245-249. 被引量:8
  • 7Bjerum S,Torp H,Kristoffersen K.Clutter filter design for ultrasound color flow imaging[J].IEEE Trans.Ultrason.Ferroelect.Freq.Contr,2002,49(2):204-216.
  • 8Yu ACH,Cobbold RSC.Single-ensemble-based eigen-processing methods for color flow imaging-part I.the Hankel-SVD filter[J].IEEE Trans.Ultrason.Ferroelect.Freq.Contr,2008,55(3):559-572.
  • 9LI P,YANG X,ZHANG D et al.Adaptive clutter filtering based on sparse component analysis in ultrasound color flow imaging[J].IEEE Trans.Ultrason.Ferroelect.Freq.Contr,2008,55(7):1582-1596.
  • 10Young B A,Song B P.Estimation of mean frequency and variance of ultrasonic doppler signal by using second-order autoregressive model[J].IEEE Trans.Ultrason.Ferroelec.Freq.Contr,1991,38(3):172-181.

二级参考文献22

  • 1陶倩,汪源源,Cardoso Jose,王威琪.管壁和血流多普勒信号的分离研究[J].声学学报,2004,29(4):329-333. 被引量:7
  • 2孟晋丽,潘泉,张洪才.基于静态小波变换的提升框架分解[J].计算机工程与应用,2005,41(6):11-13. 被引量:4
  • 3D. Evans, W. McDicken, R. Skidmore, et al. Doppler ultrasound[M]. Chichester:JohnWiley & Sons, 1989.1-20.
  • 4L. Mo, R. Cobbold. Speckle in continuous wave Doppler ultrasound spectra: asimulation study[J]. IEEE Trans UFFC,1986,33(6):747-752.
  • 5W. Wang,Q Shao. Optimum position and quasicompensation approach for quantitativemeasurement of blood flow velocity with Doppler ultrasound[J]. Journal of CardiovascularUltrasonography, 1988,5(4):289-292.
  • 6WANG Y,Fish P J.Comparison of Doppler signal analysis techniques for velocity waveform,turbulence and vortex measurement:a simulation study[J].Ultrasound Med.& Biol.,1996,22(5):635-649.
  • 7TAO Q,WANG Y,WANG W.A new method for Doppler clutter rejection based on irregular sampling and iterative spline reconstruction[J].IEEE Signal Processing Letters,2004,11(9):764-767.
  • 8TAO Q,WANG Y,Fish PJ,et al.The wall signal removal in Doppler ultrasound systems based on recursive PCA[J].Ultrasound Med.& Biol.,2004,30(3):369-379.
  • 9Signorini M G,Marchetti F,Cerutti S.Applying nonlinear noise reduction in the analysis of heart rate vari ability[J].IEEE Engineering in Medicine & Biology,2001,20(2):59-68.
  • 10Fish P J,Cardoso J C,Bastos C C.Doppler ultrasound ‘wall thump' removal with minimal loss of lowflow signal[J].ICMBE,2002,Singapore,D1I-1200.

共引文献8

同被引文献21

  • 1庞海烨,武采怡,武剑辉.彩色超声成像中回归型滤波器的设计与实现[J].生物医学工程研究,2012,31(1):20-23. 被引量:2
  • 2PETERSON R B, ATLAS L E, BEACH K W. A comparison of IIR initialization techniques for improved color Doppler wall filter per- formance [ C]//Proceedings of the 1994 IEEE Ultrasonics Symposi- um. Piscataway: IEEE, 1994:1705-1708.
  • 3YU A C H, LOVSTAKKEN L. Eigen-based clutter filter design for ultrasound color flow imaging: a review [ J], IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2010, 57(5): 1096 -1111.
  • 4YU A C H, COBBOLD R S C. A new eigen-based clutter filter u- sing the Hankel-SVD approach [ C] // Proceedings of the 2006 IEEE Ultrasonics Symposium. Piscataway: IEEE, 2006: 1079-1082.
  • 5YU A C H, COBBOLD R S C. Single-ensemble-based eigen-pro- cessing methods for color flow imaging--Part I. the Hankel-SVD fil- ter [ J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Fre- quency Control, 2008, 55(3) : 559 -572.
  • 6BJRUM S, TORP H, KRISTOFFERSEN K. Clutter filter design for ul- trasound color flow imaging [ J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2002, 49(2): 204-216.
  • 7LIU D C, KIM J, SCHARDT M. Modified autocorrelation method compared with maximum entropy method and RF cross correlation method as mean frequency estimator for Doppler ultrasound [ C]// Proceedings of the 1991 IEEE Ultrasonic Symposium. Piscataway: IEEE, 1991:1285-1290.
  • 8ZHOU X, ZHANG C, LIU D. Adaptive clutter filter in 2-D color flow imaging based on in vivo I/Q signal [ J]. Bio-Medical Materi- als and Engineering, 2014, 24(1): 307 -313.
  • 9KRUSE D E, FERRARA K W. A new high resolution color flow system using an eigendecomposition-based adaptive filter for clutter rejection [ J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2002, 49(10) : 1384 - 1399.
  • 10KADI P, LOUPAS T. On the performance of regression and step- initialized IIR clutter filters for color Doppler systems in diagnostic medical ultrasound [ J]. IEEE Transactions on Ultrasonics, Ferroe- lectrics, and Frequency Control, 1995, 42(5): 927-937.

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部