不同骨内段直径对支抗微种植体和颌骨表面影响的三维有限元分析 被引量:4

Three-Dimensional Finite Element Analysis for the Influence of Micro-Implant Endosteal Diameter on Micro-Implant and Surface of Mandibular
暂未订购
导出
摘要 目的分析支抗微种植体骨内段直径变化对颌骨应力分布和微种植体位移的影响,为临床选择微种植体和种植体优化设计提供理论参照。方法利用Pro/E软件建立不同骨内段直径的微种植体和下颌骨三维有限元模型。并用Hypermesh对所建立模型进行网格划分,用ANSYS软件进行模拟计算,在种植体顶部中央位置施加1.96N与颌骨面平行的作用力,分析在上述载荷作用下种植体的位移和骨界面应力的变化。结果随着种植体骨内段直径的增加。骨界面应力峰值和微种植体位移都减小,应力峰值主要集中在颈部和尖部。骨内段直径为1.5mm时,微种植体z轴的Von-mises应力值最小,且曲线最为平缓。颌骨表面应力峰值的面积关系为1.7mm〉1.6mm〉1.4mm〉1.5mm。结论支抗微种植体骨内段直径对微种植体应力分布有影响,在本实验条件下,微种植体骨内段为1.5mm时应力分布对颌骨损伤最小,微种植体位移最小。 Objective To analyze the stress distribution at micro-implant-bone interface and the displacement of micro-implant based on different endosteal section diameters for choosing orthodontic anchorage micro-implant and optimize design of micro-implant. Methods The finite element models of micro-implant with different endosteal section diameters and mandible were established by Pro/E software. The elements were divided by Hypermesh and the results were calculated by AnsyslO.0. A force of 1.96 N was apphed on the top of the implant parallel to the mandible surface to analyze the differences of the micro-implant displacement and that of the force on the micro-implant-bone interface. Results With the increasing diameter of endosteal section, both the maximum Von-mises stress on micro-implant-bone interface and the maximum displacement in micro-implant decreased. The maximum Von-mises stress focused on the neck and the tip of micro-implant. The Von-mises stress of micro-implant on z axis was the smallest, and the stress curved was the flattest at the endosteal section diameter of 1.5 mm than that of other sizes. The tendence of the contour map area for mandible surface stress was 1.7 mm〉1.6 mm〉1.4 mm〉1.5 mm. Conclusion The influence of the micro-implant diameter in-bone on the micro-implant is significant. The damage on the mandible and the displacement of the micro-implant are both the smallest in the 1.5 mm case.
出处 《天津医药》 CAS 北大核心 2013年第1期22-25,I0001,共5页 Tianjin Medical Journal
关键词 有限元分析 应力 物理 正畸支抗 下颌骨 微种植体 finite element analysis stress, mechanical orthodontic anchorage procedures mandible micro-implant
  • 相关文献

参考文献11

二级参考文献56

共引文献53

同被引文献38

  • 1邓锋,张磊,张翼,宋锦璘,樊瑜波.微植体支抗-骨界面的生物力学研究及微植体颈部优化设计探讨[J].四川大学学报(医学版),2007,38(4):701-704. 被引量:10
  • 2Kitahara-Cdia FM, AssadoLoss TF, Mucha JN, et al. Morphological evaluation of the active tip of six types of orthodontic mini-implants[J]. Dental Press J Orthod, 2013, 18(2):36-41.
  • 3Lin TS, Tsai FD, Chen CY, et al. Factorial analysis of variables affecting bone stress adjacent to the orthodontic anchorage mini-implant with finite ele- ment analysis[J]. Am J Orthod Dentofacial Orthop, 2013, 143(2):182-189.
  • 4Monnerat C, Restle L, Mucha JN, Tomographic mapping of mandibular interradicular spaces for placement of orthodontic mini-implants[J]. Am J Orthod Dentofacial Orthop, 2009, 135(4):428.el- 428.e9.
  • 5Karmarker S, Yu W, Kyung HM. Effect of surface anodization on stability of orthodontic microimplant [J]. Korean J Orthod, 2012, 42(1):4-10.
  • 6Lan TH, Du JK, Pan CY, et al. Biomechanical ana- lysis of alveolar bone stress around implants with different thread designs and pitches in the mandi- bular molar area[J]. Clin Oral Investig, 2012, 16(2): 363-369.
  • 7Abrahamsson I, Berglundh T. Tissue characteristics at microthreaded implants: an experimental study in dogs[J]. Clin Implant Dent Relat Res, 2006, 8(3): 107-113.
  • 8Brinley CL, Behrents R, Kim KB, et al. Pitch and longitudinal fluting effects on the primary stability of miniscrew implants[J]. Angle Orthod, 2009, 79 (6):1156-1161.
  • 9Alves M Jr, Baratieri C, Nojima LI. Assessment of mini-implant displacement using cone beam com- puted tomography[J]. Clin Oral Implants Res, 2011, 22(10):1151-1156.
  • 10Wilmes B, Ottenstreuer S, Su YY, et al. Impact of implant design on primary stability of orthodontic mini-implants[J]. J Orofac Orthop, 2008, 69(1):42- 50.