期刊文献+

实时透视触发三维增强磁共振颈部血管成像技术47例临床分析

Clinical Analysis of 47 Cases of Three Dimensional Contrast Enhanced Magnetic Resonance Angiography with Real-Time Fluoroscopic Triggering
暂未订购
导出
摘要 目的探讨实时透视触发三维增强磁共振颈部血管成像技术,评价分析47例临床应用效果.方法回顾性分析2012年1月—2012年3月期间完成的47例实时透视三维增强磁共振颈部血管成像,根据制定的分级标准评判图像质量,探讨该成像技术的方法,并评价其临床应用效果.结果 47例实时透视三维增强磁共振颈部血管成像,其对颈部Ⅰ~Ⅳ血管的显示优秀者(4分)27例,占57%,良好者(3分)13例,占28%,两者共40例,显像优良率占85%;中等者(2分)3例,占6%;差者1例,占2%;失败者(0分)3例,占6%.与BOLUS-TEST和SMART-PREP方法比较,P>0.05,无统计学意义.结论实时透视触发三维增强磁共振血管成像技术成熟,操作简便易行,显像效果良好,可开展应用于颈部血管疾病的影像诊断. Objective To discuss three dimensional contrast enhanced magnetic resonance angiography with real-time fluoroscopic triggering in carotid arteries,and the clinical application of 47cases were evaluated and analyzed.Method Retrospective analysis of 47 cases with three dimensional contrast enhanced magnetic resonance angiography with real-time fluoroscopic triggering in carotid arteries from January 2012 to March 2012,according to the classification standard of image quality,discussing the imaging methods and evaluation of its clinical application.Results In these 47 cases of three dimensional contrast enhanced magnetic resonance angiography with real-time fluoroscopic triggering in carotid arteries,27cases showed the 1 to four grade carotid arteries very well(4 scores),accounted for 57%,13 cases well(3 scores),28%,the both is 85%,3 cases showed medium(2 scores),6%,1 cases is bad(1 scores),2%,and 3 cases are failure,6%.Compare to BOLUS-TEST and SMART-PREP,P0.05,no significant difference.Conclusion The three dimensional contrast enhanced magnetic resonance angiography with real-time fluoroscopic triggering in carotid arteries technique is mature and reliable,and operate simply,imaging well.It is feasible to diagnose carotid disease.
机构地区 南京市中医院
出处 《北华大学学报(自然科学版)》 CAS 2012年第6期686-688,共3页 Journal of Beihua University(Natural Science)
关键词 实时透视触发 三维增强 磁共振血管成像 颈部血管 real-time trigging three dimensional contrast enhanced magnetic resonance angiography cervical vascular
  • 相关文献

参考文献6

二级参考文献27

  • 1韩鸿宾,沙琳,刘洪东,张树墩,刘溢,边杰,董志.MR快速多时相造影增强与时间飞跃血管成像在颈部血管疾病中诊断价值的对比研究[J].中华放射学杂志,2004,38(7):737-741. 被引量:17
  • 2张照喜,陈宪,徐宁,刘玉林,郑之青,蒋春林.三维增强MR血管成像个性化方案的确定:iPass技术的临床应用[J].中华放射学杂志,2005,39(9):983-986. 被引量:11
  • 3何玲,陈建,袁红梅,杜先懋,王苇,李澄.颈动脉CE-MRA技术的探讨[J].放射学实践,2005,20(12):1072-1074. 被引量:5
  • 4Maki JM,Prince MR,Londy FJ,et al. The effect of time varying intravascular singal intensity and K - space acquisition order on three - dimensional MR angiography image quality[ J]. Magn Reson Imaging, 1996,6( 3 ) :642 - 651.
  • 5Luccichenti G, Cademartiri F, Lucidi V, et al. MR angiography of the carotid arteries : parameters affecting image quality [ J ]. Acad Radiol, 2003,10 ( 5 ) ': 520 - 526.
  • 6Earls JP,Rnfsky NM, DeCorato DR, et al. Breath - hold single - dose gadolinium - enhanced three - dimensional MR aortography: usefulhess of a timing examination and MR power injector[ J ]. Radiology, 1996,201 (3) :705 - 710.
  • 7Foo TK, Saranathan M, Prince MR, et al. Automated detection of bolus arrival and initiation of data acquisition in fast, three - dimensional, gadolinium - enhanced MR angiography [ J ]. Radiology, 1997,203 (1) :275 -280.
  • 8Lee JJ,Tirman PJ, Chang Y, et al. The optimiztion of scan timing for contrast - enhanced magnetic resonance angiography [ J ]. Korean J Radiol,2000,1 ( 3 ) : 142 - 151.
  • 9Maki JH,Prince MR,Londy FJ,et al.The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality.J Magn Reson Imaging,1996,6:642-651.
  • 10Riederer SJ,Bernstein MA,Breen JF,et al.Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering:design specifications and technical reliability in 330 patient studies.Radiology,2000,215:584-593.

共引文献77

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部