填料吸收塔实验操作条件的优化 被引量:1

Determination on Operating Condition for Packing Column Absorption Experiment
在线阅读 下载PDF
导出
摘要 文章对现有的填料塔中水吸收CO2体系的操作条件进行分析研究。分析了CO2的浓度,空气流量、吸收剂用量等因素对填料吸收塔的吸收效率的影响,通过单因素和正交实验验证,确定最佳的实验操作条件:空气流量为1.5 m3/h,清水流量为400 L/h,CO2流量为40 m3/h。 The paper embarked a research and analysis on the operating conditions of existing column which the included water can absorb CO2 system. And analyzed the efficiency influence of COils density, factors and so on air flow and absorbent amount used to the padding absorption tower's absorption. Through the single factor and the orthogonal experimental verification, it obtained the best operating condition: the air flow was 1.5 m^3/h, the clear water current capacity was the 400 L/h, and the CO2's current capacity was 40 m^3/h.
出处 《广东化工》 CAS 2012年第16期190-191,共2页 Guangdong Chemical Industry
关键词 吸收 填料塔 吸收效率 操作条件 absorption packing column: efficiency influence: operating condition
  • 相关文献

参考文献5

  • 1陈敏恒,丛德滋,方图南,等.化工原理·下册·第三版[M].北京:化工工业出版社,2006: 7.
  • 2阮奇,叶长焱.填料塔吸收率汇总[M].北京:化学工业出版社,153-154.
  • 3周建伟.填料塔吸收实验设计改进和应用[J].新乡学院学报,1995,0(2):46-48. 被引量:1
  • 4姚玉英.化工原理天津:科学技术出版社,1998:4-12.
  • 5黄玉春.大连理工大学化工原理教研室.化工原理(下)[M].北京:高教出版社,1990: 66-78.