测量了溴化亚铜激光器放电电流和激光脉冲波形之间的延迟时间与放电管管壁温度的关系 ,发现放电电流和光脉冲间的延迟时间随工作温度的升高而缩短 ,并与纯铜激光器的黄绿光时间行为作了比较 ,定性分析了产生这一现象的原因。
The relationship of the delay- time of discharge current and lightpulse depends on the discharge tube temperature has been measured.It was found that the delay- time of electro- photo pulse decreases when the tube temperature increases and the time behavior of yellow- green light is compared with that of pure copper laser.A simple course was given to explain the result.