摘要 目的评价应用缩短呼吸指令时间的团注示踪法(bolus-tracking)行大螺距双源CT冠状动脉成像(CCTA)获得图像的增强效果及有效辐射剂量。方法收集临床疑诊为冠状动脉性心脏病的184例患者,随机平均分为两组:A组92例,采用大螺距前瞻性心电门控螺旋扫描(Flash Spiral)模式、缩短呼吸指令时间的bolus-tracking法扫描;B组92例,采用测试团注法(test-bolus)扫描。对两组图像的主动脉根部CT值、图像噪声、CNR及有效辐射剂量进行统计学比较。结果两组图像主动脉根部CT值、图像噪声、CNR间的差异均无统计学意义(P均>0.05)。两组触发时、扫描过程中辐射剂量差异均无统计学意义(P均>0.05)。结论双源CT大螺距前瞻性心电门控螺旋扫描CCTA中,采用缩短呼吸指令时间的bolus-tracking法可获得与test-bolus法相近的图像增强效果,而对比剂用量进一步减低。 Objective To assess the enhancement effect and radiation doses of coronary computed tomography angiogra phy (CCTA) using bolus-tracking technique shortened instructional time of respiration with high-pitch dual-source CT (DSCT). Methods Totally 184 patients of suspected coronary artery disease were collected, and were randomly divided in to two groups. Patients in group A (n=92) underwent CCTA using bolus-tracking technique shortened instructional time of respiration with high-pitch spiral acquisition mode (Flash Spiral mode), while in group B (n=92) underwent CCTA u sing test-bolus technique. CT value of the ascending aorta, image noise, CNR and radiation doses of two groups were as sessed. Results There was no significant difference for CT value of the ascending aorta, image noise, CNR between the two groups (all P〉0.05). There were no significant differences in the radiation dose of dynamic monitorirLg scans and the angiographic between the two groups (all P〉0.05). Conclusion In high-pitch DSCT, comparing with test-bolus tech nique, bolus-tracking technique and shortened instructional time of respiration can acquire similar enhancement effect, while the average effective radiation dose of dynamic monitoring scans and contrast medium volume are significantly reduced.
出处 《中国医学影像技术》 CSCD 北大核心 2012年第11期2083-2086,共4页 Chinese Journal of Medical Imaging Technology
关键词 冠状血管造影术 体层摄影术 X线计算机 辐射剂量 Coronary angiography Tomography, X-ray computed Radiation dosage
  • 相关文献

参考文献2

二级参考文献9

  • 1Hassan A, Nazir SA, Alkadhi H. Technical challenges of coro-nary CT angiography:Today and tomorrow. Eur J Radiol, 2011, 79(2) : 161-171. Mar 11. [Epub ahead of print].
  • 2Leschka S, Stolzmann P, Desbiolles L, et al. Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary ste- noses: first experience. Eur Radiol, 2009,19(12) :2896-2903.
  • 3Lell M, Hinkmann F, Anders K, et al. High-pitch electrocardio- gram triggered computed tomography of the chest: initial results. Invest Radiol, 2009,44(11) :728-733.
  • 4Bamberg F, Marcus R, Sommer W, et al. Diagnostic image qual- ity of a comprehensive high-pitch dual-spiral eardiothoracic CT protocol in patients with undifferentiated aeute chest pain. Eur J Radiol, 2010, Dec 31. [Epub ahead of print].
  • 5Achenbach S, Marwan M, Ropers D, et al. Coronary computed tomography angiography with a consistent dose below lmSv using prospectively electrocardiogram-triggered high-pitch spiral acqui- sition. Eur Heart J, 2010,31(3) :340-346.
  • 6Blankstein R, Shah A, Pale R, et al. Radiation dose and iamge quality of prospective triggering with dual-source cardiac compu- ted tomography. Am J Cardiol, 2009,103(8) : 1168-1173.
  • 7Scheffel H, Alkadhi H, Plass A, et al. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test prob- ability without heart rate control. Eur Radiol, 2006, 16 (12): 2739-2747.
  • 8Patel SI, Souter MJ. Equipment-related electrocardiographic arti facts: causes, characteristics, consequences, and correction. An esthesiology, 2008,108(1) :138-148.
  • 9王怡宁,李烁,孔令燕,王志伟,周慷,曹剑,樊红苓,张晓娜,张竹花,金征宇.低剂量双源CT前瞻性心电触发大螺距扫描冠状动脉造影的图像质量和放射剂量[J].中国医学科学院学报,2010,32(6):597-600. 被引量:21

共引文献14

同被引文献9

引证文献2

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部