摘要
睢宁水厂取水工程设计规模10万m3/d,水源取自庆安水库,采用两种取水方案进行比较,方案一为框架式取水头部、架空虹吸钢管引水;方案二为箱式取水头部、钢管埋地敷设,通过两种方案比较,得出了方案二具有投资低,施工方便及安全性高的优点,并针对该方案施工中的要点提出相应的技术措施,为取水工程的设计提供参考。
The capacity of water intake project for Suining water treatment plant is lOs m3/d. Raw water designed to be taken from Qing'an reservoir. Two schemes for this water intake project were compared. A raw water extraction head of framework structure was designed as scheme I with stilted steel syphon pipe for water transportation and raw water extraction head of box structure was designed as scheme II with steel pipe buried underground for water transportation.Scheme II possesses the advantages of low investment, convenience to construction and safety to operation as compared with scheme I. Some technical measures were pointed out. which were exnected to be references to the desiL, n.
出处
《净水技术》
CAS
2012年第5期76-78,共3页
Water Purification Technology
关键词
框架式取水头部
虹吸管
箱式取水头部
设计方案比选
frame-type water intake head syphon pipe box-type water intake head scheme selection of design