期刊文献+

平台转换连接种植体基台穿龈高度对皮质骨应力的影响 被引量:1

The Effect of Abutment with Different Height Through Gingiva on Stress Distribution of Cortical Bone Using Platform Switching
暂未订购
导出
摘要 目的:研究平台转换连接种植体中基台的穿龈高度对皮质骨应力的影响。方法:利用Solidworks2007制图软件,模拟平台转换连接种植体-基台和Ⅱ类骨在基台不同穿龈高度时的模型,导入Ansys workbench11.0有限元分析软件,采用垂直和45°斜向2种方向加载,分析基台不同穿龈高度(0.75mm、1.5mm、3.0mm、4.5mm、6.0mm)时的应力分布,对结果用SAS8.2统计软件进行方差分析。结果:不同穿龈高度间皮质骨最大应力差异有统计学意义(P<0.05),当穿龈在3.0~4.5mm之间时,最大应力值趋向稳定。结论:随基台穿龈高度增加,Ⅱ类骨皮质骨最大应力有增大趋势,但当穿龈高度在3.0~4.5mm之间时最大应力几乎没有变化。 Objective: To exeplore the effect of abutments with different height through gingiva on the stress distribution of cortical bone.Methods: Using Solidworks2007 mapping software,we established the model of implant-abutment in type Ⅱbone area with abutments of different height through gingiva.The model was loaded vertically and 45-degree from the abutment using Ansys-workbench11.0 finite element analysis software.Then we analyzd the stress distribution on conditions of different abutment height through gingiva(0.75mm,1.5mm,3.0mm,4.5mm,6.0mm),The results were analysed with SAS8.2 statistical software using ANOVA.Results: The difference of the stress on cortical bone with different height of the abutment through gingival is significant(P0.05).The maximum stress on cortical bone will remain in a steady state when the height of the abutment through gingival is 3.0-4.5mm.Conclusion: The maximum stress of cortical bone has an increasing trend as the increasing of the height of the abutment through gingiva.Yet the maximal stress will have little change when the height of the abutment through the gingival is 3.0-4.5mm.
出处 《口腔医学研究》 CAS CSCD 2012年第10期1035-1037,共3页 Journal of Oral Science Research
关键词 种植体 平台转换 应力分布 皮质骨 Implant Platform Switching Stress Distribution Cortical bone
  • 相关文献

参考文献10

  • 1付丽,周延民,李春艳,王林,阿兰.平台转换连接对种植体-骨界面应力分布的影响[J].口腔医学研究,2010,26(6):827-829. 被引量:7
  • 2Lekholm U, Zarb GA. Patient selection and preparations [A]. In: Brhnemark P-I, Zarb GA, Albrektsson T (eds).Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry [M]. Cb_icago: Quintessence, 1995: 199-209.
  • 3ErikoKitarnura, Roxana Stegaroiu, ShuichiNomura, et a. 1 Bio-mechanical aspects of marginal bone resorption around osseointe-grated implants: considerationsbased on a three- dimensional finite element analysis [J]. Clin Oral Implants, 2004, 15(3) : 401-412.
  • 4Cochran DL. The scientific basis for clinical experiences with Straumann implants including the ITI dental implant system: A consensus report[J]. Clin Oral Implant Res, 2000, 11(1) : 33-58.
  • 5Hojjatie B, Anusaviee KS. Three dimensional finite element analyses of glass ceramic dental crowns[J].J Biomechanics, 1990, 23(11) : 1157-1166.
  • 6康非吾,卢军,潘可风.种植区骨皮质厚度对种植体骨界面应力分布的影响[J].同济大学学报(医学版),2006,27(1):31-33. 被引量:24
  • 7Morneburg TR, Proschel PA. Measurement of masticatory forces and implant loads: a methodologic clinical study[J]. Int J Prosthodont, 2002, 15(1) : 20-27.
  • 8Tabata LF, Assunc~o WG, Adelino Ricardo Barfo V, et al. Implant platform switching: biomechanieal approach using two-dimensional finite element analysis [J].J Craniofac Surg, 2010, 21(1) : 182-187.
  • 9Sevimay M, Usumez A, Eskitaseioglu G. The influence of various oeclusal materials on stresses transferred to implant- supported prostheses and supporting bone: A three-dimen- sional finite-element study [J]. J Biomed Mater Res B Appl Biomater, 2005, 73(1) : 140-147.
  • 10Naert I, Koutsikakis G, Quirynen M, etal. Biologic out- come of implant- supported restorations in the treatment of partial edentulism. Part 2: a longitudinal radiographic study[J].J Clin Oral Implants Res, 2002, :13(4) : 390-395.

二级参考文献13

  • 1Otto M.Concept of implant platform switching[J].SADJ,2007,62(2):80.
  • 2Baumgarten H,Cocchetto R,Testori T,et al.A new implant design for crestal bone preservation:Initial observations and case report[J].Pract Proced Aesthet Dent,2005,17(10):735-740.
  • 3Albrektsson T,Zarb G,Worthington P,et al.The long-term efficacy of currently used dental implants:Areview and proposed criteria for success[J].Int J Oral Maxillofac Implants,1986,1(1):11-25.
  • 4George F.The Esthetic Challenge of Adjacent Implants[J].J Oral Maxillofac Surg,2007,65(7):2-12.
  • 5Hermann F.Lerner H.Palti A.Factors influencing the preservation of the periimplant marginal bone[J].Implant Dent,2007,16(2):165-175.
  • 6Calvo Guirado JL.Saez Yuguero MR.Pardo Zamora G.,et al.Immediate provisionalization on a new implant design for esthetic restoration and preserving crestal bone[J].Implant Dent,2007,16(2):155-164.
  • 7Naert I,Koutsikakis G,Quirynen M,et al.Biologic outcome of implant-supported restorations in the treatment of partial edentulism.Part 2:a longitudinal radiographic study[J].J Clin Oral Implants Res,2002,13(4):390-395.
  • 8Maeda Y,Miura J,Taki I,et al.Biomechanical analysis on platform switching:is there any biomechanical rationale[J] ? Clin Oral Implants Res,2007,18(5):581-584.
  • 9Sevimay M,Turhan F,Kilicarslan MA,et al.Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown[J].J Prosthet Dent,2005,93(3):227-234.
  • 10Glauser R,Ruhstaller P,Windisch S,et al.Immediate occlusal loading of Branemark System TiUnite implants placed predominantly in soft bone:4-year results of a prospective clinical study[J].Clin Implant Dent Relat Res,2005,7(1):S52-59.