The Transient Modal Dynamic Analysis of a Coke Tower

The Transient Modal Dynamic Analysis of a Coke Tower
在线阅读 下载PDF
导出
摘要 Dynamic analysis must be performed when the duration of the applied load is short or if the load is dynamic in nature. Wind load, as a random load, can lead to the vibration of the coke tower. In order to study the influence to the strength of the coke tower by wind, ABAQUS was used to conduct the transient modal dynamic analysis of the wind load. The response of the structure during loading and unloading was mainly observed. The results indicate that, with the effect of wind, the maximal nodal displacement appears at the top of the tower, which is 0.79 mm; while the maximal stress locates at the node around the skirt, the maximum is 3.26 MPa. Both of the displacement and stress cannot cause the failure of the structure. After loading and unloading, the structure engenders vibration along the loading direction. The frequency is 10 Hz, under the effect of external loads, it may easily cause the resonance of the structure, which can cause damage to the structure. So it must be taken into consideration during the process of design and operation. Dynamic analysis must be performed when the duration of the applied load is short or if the load is dynamic in nature. Wind load, as a random load, can lead to the vibration of the coke tower. In order to study the influence to the strength of the coke tower by wind, ABAQUS was used to conduct the transient modal dynamic analysis of the wind load. The response of the structure during loading and unloading was mainly observed. The results indicate that, with the effect of wind, the maximal nodal displacement appears at the top of the tower, which is 0.79 mm; while the maximal stress locates at the node around the skirt, the maximum is 3.26 MPa. Both of the displacement and stress cannot cause the failure of the structure. After loading and unloading, the structure engenders vibration along the loading direction. The frequency is 10 Hz, under the effect of external loads, it may easily cause the resonance of the structure, which can cause damage to the structure. So it must be taken into consideration during the process of design and operation.
出处 《International Journal of Plant Engineering and Management》 2012年第3期187-192,共6页 国际设备工程与管理(英文版)
关键词 wind load coke tower dynamic analysis VIBRATION RESONANCE wind load; coke tower; dynamic analysis; vibration; resonance
  • 相关文献

参考文献2

二级参考文献16

共引文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部