摘要
红沿河核电站海水淡化系统于2010年6月调试可用。经过一段时间试运行后,发现V型滤池底部挑耳裸露钢筋及滤池滤板紧固件等锈蚀严重,分析了腐蚀原因,并介绍了所采取的防护措施。
The seawater desalination system of Hongyanhe Nuclear Power Plant is debugged available in June 2010. After a period of trial operation, it is found that the bare steel of the V-filter bottom and the filter plate fasteners corraded seriously. This paper analyzes the reasons for corrosion, and describes the protective meansures taken.
出处
《东北电力技术》
2012年第8期31-34,共4页
Northeast Electric Power Technology
关键词
核电站
海水淡化
V型滤池
防腐处理
Nuclear power plant
Seawater desalination
V-filter
Anti-corrosin