摘要
介绍了使用密封气体三相点瓶复现e-H_2、e-D_2和Ne三相点的试验装置和复现方法。文未简单介绍了数据处理方法,并给出了它们在1986~1988年的复现结果。
The testing device and method of repeating e-H_2, e-D_2 and Ne triple point by using sealed air triple point bottle are introduced. The data processing method and the repeating results obtained during the period of 1986 to 1989 are presented finally.
出处
《自动化仪表》
CAS
北大核心
1990年第3期21-23,共3页
Process Automation Instrumentation