摘要 利用新开发的铀试剂包和自行研制的手持式光度计,建立了环境水样中痕量铀的现场分析新方法。实验中分别考察了缓冲试剂、显色剂、掩蔽剂的选择及用量、显色时间稳定性、波长等主要因素对铀分析测定的影响。结果表明,与经典紫外-可见分光光度法相比,此方法具有操作简便、省时、满足现场测定要求等优点。 Based on the newly developed uranium reagent wrap and homemade handheld photometer, we developed a new method for detecting trace uranium in water from the environment. The influences of different experimental conditions, such as buffer solution, concentration of indicator and masking rea- gent, time and wavelength, were studied in this contribution. The results suggest that the new developed method is simple, time-saving and suitable for field analysis, which is superior to conventional UV-visible spectroscopy that needs complex steps.
出处 《铀矿地质》 CAS CSCD 2012年第5期311-316,320,共7页 Uranium Geology
基金 国家重大科学仪器设备专项资助(No.2011YQ15004016) 江西省科技厅科技计划项目资助(No.DHBK1006) 东华理工大学博士启动金资助(No.DHBK1006)
关键词 试剂包 现场分析 手持式光度计 环境水 reagent wrap in-situ analysis handheld photometer environment water uranium
  • 相关文献

参考文献15

二级参考文献49

共引文献52

同被引文献26

  • 1胡明松.液相色谱与电感耦合等离子体原子发射光谱联用分离和检测四价和六价铀[J].分析化学,2005,33(2):173-176. 被引量:3
  • 2王学求.地气的研究现状与未来[J].国外地质勘探技术,1996(5):12-18. 被引量:15
  • 3杨静,廖力夫,刘运美,袁金涛.催化动力学褪色光度法测定痕量铀(Ⅵ)的研究[J].南华大学学报(自然科学版),2006,20(3):91-93. 被引量:3
  • 4吴涛,康厚军,张东.水中铀的电感耦合等离子体发射光谱法测定[J].分析测试学报,2007,26(6):845-846. 被引量:23
  • 5Gibson J K,Marcalo J.2006.New Development in Gas-Phase Actinide Ion Chemistry[J].Coord.Chem.Rev.,250:776-783.
  • 6Kulich M,Rericha V,Rericha R,et al..2011.Incidence of non-lung solid cancers in Czech uranium miners:a case-cohort study[J].Environ.Res.,111 (3):400-405.
  • 7Lee J H,Wang Z D,Liu J W,et al.2008.Highly Sensitive and Selective Colorimetric Sensors for Uranyl (UO22+):Development and Comparison of Labeled and Label-Free DNAzyme-Gold Nanoparticle Systems[J].J.Am.Chem.Soc.,130(43):14217-14226.
  • 8Liu J W,Brown A K,Meng X L,et al.2007.A catalytic beacon sensor for uranium with parts-pertrillion sensitivity and millionfold selectivity[J].Proc.Natl.Acad.Sci.,104(7):2056-2061.
  • 9Luo M B,Hu B,Zhang X,et al.2010.Extractive Electrospray Ionization Mass Spectrometry for Sensitive Detection of Uranyl Species in Natural Water Samples[J].Anal.Chem.,82(1):282-289.
  • 10Walsh L,Dufey F,M(o)hner M,et al.2011.Differences in baseline lung cancer mortality between the German uranium miners cohort and the population of the former German Democratic Republic (1960-2003)[J].Radit.Environ.Biophys.,50(1):57-66.

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部