摘要 目的探讨微创内固定系统(LISS)治疗股骨远端骨折的疗效。方法应用LISS钢板治疗32例股骨远端骨折患者。结果 32例均获随访,时间12~24(16±2.6)个月。未发现关节面塌陷、复位丢失、螺钉固定不良等现象。按照膝关节HSS评分标准评分:优16例,良13例,可2例,差1例,优良率为90.6%。结论 LISS钢板治疗股骨远端骨折设计合理,操作简便,固定可靠,疗效满意。 Objective To explore the results of the treatment of distal femoral factures with less invasive stabilization system(LISS). Methods 32 patients with distal femur fractures were treated by LISS. Results 32 cases were followed up for 12 - 24( 16 :t: 2. 6)months. there was no joint surface subsidence and reduction loss or screws malposition. According to the HSS system, the results were excellent in 16 cases, good in 13, fair in 2, and poor in 1, with 90.6% rate of good or excellent. Conclusions LISS is consistent with the principles of biological osteosynthesis on the design, and the system offers a new and effective internal fixation method for treatment.
出处 《临床骨科杂志》 2012年第4期441-442,共2页 Journal of Clinical Orthopaedics
关键词 股骨骨折 骨折固定术 微创内固定系统 femoral fractures fracture fixation, internal less invasive stabilization system.
  • 相关文献

参考文献2

二级参考文献7

  • 1周方,张志山,田云,姬洪全.微创内固定系统治疗复杂股骨转子部骨折的初步报告[J].中华创伤骨科杂志,2006,8(12):1113-1117. 被引量:42
  • 2Merchant T C, Dietz F R. Long-term follow-up after operation of the tibial and fibular shaft [ J ]. J Bone Joint Surg Am, 1989,71 (4) :599 -606.
  • 3Zlowodzki M, Williamson S, Cote P A, et al. Biomechanical evaluation of the less invasive stabilization system, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures [ J ]. J Orthop Trauma,2004,18 ( 8 ) :494 - 502.
  • 4Kregor P J,Stannard J,Zlowodzki M,et al.Distal femoral fracture fixation utilizing the Less Invasive Stabilization System (LISS):the technique and early results[J].Injury,2001,32(S3):SC32-47.
  • 5Schutz M,Kaab M J,Haas N.Stabilization of proximal tibial fractures with the LIS-System:early clinical experience in Berlin[J].Injury,2003,34(Suppl 1):A30-35.
  • 6Schutz M,Muller M,Regazzoni P,et al.Use of the less invasive stabilization system (LISS) in patients with distal femoral (AO33) fractures:a prospective multicenter study[J].Arch Orthop Trauma Surg,2005,125(2):102-108.
  • 7Fankhauser F,Gruber G,Schippinger G,et al.Minimal-invasive treatment of distal femoral fractures with the LISS(Less Invasive Stabilization System):a prospective study of 30 fractures with a follow up of 20 months[J].Acta Orthop Scand,2004,75(1):56-60.

共引文献28

同被引文献97

引证文献12

二级引证文献82

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部