摘要 近年来,电气火灾监控系统已经逐渐成为建筑消防电气设计中必须考虑的重要部分。本文概述了电气火灾监控系统的组成及原理,并结合工程设计实例给出了相关的系统结构方案,最后针对剩余电流式电气火灾监控探测器在项目应用中应注意的问题进行了探讨。 Electrical fire monitoring system has gradually become an important part that must be considered in building fire fighting electrical design in recent years. This paper outlines the conposition and priciple of electrical fire monitoring system, and gives related system structure scheme combining with project cases, finally it discusses the problems should be noticed in application of residual current electrical fire monitoring detector.
出处 《智能建筑电气技术》 2012年第4期76-80,共5页 Electrical Technology of Intelligent Buildings
关键词 电气火灾 监控系统 监控探测器 ARCM 设计 electrical fire, monitoring system, monitoring detector, ARCM, design
  • 相关文献

参考文献5

  • 1中华人民共和国公安部.沈阳消防研究所.GBl42872005电气火灾监控系统[S].北京:中国标准出版社,2005.
  • 2北京供电局.上海电器科学研究所.GBl3955-2005剩余电流动作保护装置安装和运行[S].北京:中国标准出版社,2005.
  • 3国家技术监督局.中华人民共和国住房和城乡建设部.GB50045-95(2005版)高层民用建筑设计防火规范[S].中北京:国计划出版社,2005.
  • 4中华人民共和国公安部.GB50026-2006,建筑设计防火规范[S].北京:中国计划出版社,2006.