摘要 对几种 6 0万千瓦锅炉顶棚包墙系统进行对比 ,提出了减少钢耗、减小阻力 。 A comparison was conducted of several versions of superheater roof enclosure wall system for a 600 MW boiler. On this basis proposed are some measures to decrease the steel consumption and flow resistance of the system as well as to ensure its operation reliability.
出处 《热能动力工程》 CAS CSCD 北大核心 2000年第2期142-144,共3页 Journal of Engineering for Thermal Energy and Power
关键词 顶棚包墙 过热器 阻抗 电站锅炉 boiler, roof enclosure wall, superheater, flow resistance, improvement