期刊文献+

不同厚度上颌中切牙全瓷冠应力分布的有限元研究 被引量:6

Finite element stress analysis of all-ceramic crown of the upper central incisor in differential thickness
暂未订购
导出
摘要 目的研究不同厚度上颌中切牙全瓷冠受载时的应力分布特点。方法利用上颌中切牙全瓷冠的三维有限元模型,对3种不同厚度的全瓷冠分别进行100、150、200 N载荷模拟加载,并进行力学分析。结果不同厚度全瓷冠不同载荷下的应力分布趋势相似,应力集中于冠的颈缘及加载点。随着厚度增加,应力集中趋势明显减弱。随着载荷增加,各部位的等效应力相应增加,加载点及颈缘尤为明显。结论全瓷冠厚度的增加可降低应力集中。颈缘和加载点为应力集中区,全冠制作时应注意加强该区域。 Objective To investigate the stress distributions under load in an all-ceramic crown of the upper cen-tral incisor in differential thickness.Methods The 3-dimensional finite element model of all-ceramic crown of the upper central incisor in differential thickness was applied with differential loads(100,150,200 N).The stress values and distributions of all-ceramic crown were calculated and expressed.Results The tendency of stress distributions in all-ceramic crown of differential thickness and loads was similar.The maximal stress intensity value was located in the loading site and the cervical region.As the thickness of all-ceramic crown increased,the stress concentration re-duced.When the load increased,the stress values increased,especially in the loading site and the cervical region.Conclusion The increasing of the thickness of all-ceramic crown will decrease stress concentration.Because stress concentration is mainly in cervical region and loading site,these regions should be cared in fabrication of all-ceramic crown.
出处 《华西口腔医学杂志》 CAS CSCD 北大核心 2012年第4期356-359,共4页 West China Journal of Stomatology
基金 江苏省高校高新技术产业化推广基金资助项目(JH10-27) 南京医科大学科学发展基金资助项目(NY04028) 江苏高校优势学科建设工程基金资助项目(2011年)
关键词 全瓷冠 三维有限元模型 应力分布 上颌中切牙 all-ceramic crown 3-dimensional finite element model stress distribution upper central incisor
  • 相关文献

参考文献18

  • 1Yettram AL, Wright KW, Pickard HM. Finite element stress ana- lysis of the crowns of normal and restored teeth[J]. J Dent Res, 1976, 55 (6) : 1004-1011.
  • 2Liu B, Lu C, Wu Y, et al. The effects of adhesive type and thi- ckness on stress distribution in molars restored with all-ceramic crowns[J]. J Prosthodont, 2011, 20(1):35-44.
  • 3Hojjatie B, Anusavice KJ. Three--dimensional finite element ana- lysis of glass-ceramic dental crowns[J]. J Biomech, 1990, 23(11): 1157-1166.
  • 4Pallis K, Griggs JA, Woody RD, et al. Fracture resistance of three all--ceramic restorative systems for posterior applications[J]. J Pros- thet Dent, 2004, 91 (6) : 561-569.
  • 5Bhowmick S, Zhang Y, Brian RL. Competing fracture modes in brittle materials subject to concentrated cyclic loading in liquid environments: Bilayer structures[J]. J Mater Res, 2005, 20(10): 2792-2800.
  • 6Snyder MD, Lang BR, Razzoog ME, The efficacy of luting all- ceramic crowns with resin-modified glass ionomer cement[J]. J Am Dent Assoc, 2003, 134(5):609-612, quiz 632-633.
  • 7Rekow ED, Harsono M, Janal M, et al. Factorial analysis of vari- ables influencing stress in all-ceramic crowns[J]. Dent Mater, 2006, 22(2) : 125-132.
  • 8Thompson JY, Anusavice KJ, Naman A, et al. Fracture surface characterization of clinically failed all-ceramic crowns[J]. J Dent Res, 1994, 73(12) : 1824-1832.
  • 9Rosenblum MA, Sehulman A. A review of all--ceramic restorations[J]. J Am Dent Assoc, 1997, 128(3):297-307.
  • 10Coelho PG, Silva NR, Thompson VP, et al. Effect of proximal wall height on all-ceramic crown core stress distribution: A finite ele- ment analysis study[J]. Int J Prosthodont, 2009, 22(1):78-86.

二级参考文献12

共引文献48

同被引文献47

引证文献6

二级引证文献63

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...