摘要 目的采用MSCT肺静脉成像对肺静脉进行定量观察。方法选择冠状动脉CTA结果正常的500例患者的影像资料,收集心脏原始图像及肺静脉后处理图像,确定心室舒张早期及收缩早期,测量不同时相各肺静脉径线,统计各肺静脉解剖类型、变异及分型。结果 4种肺静脉类型中,Ⅰ型443例(443/500,88.60%),Ⅱ型17例(17/500,3.40%),Ⅲ型4例(4/500,0.80%),Ⅳ型36例(36/500,7.20%)。同一心动周期不同时相肺静脉形态及径线不同,在心室舒张早期时最大,而在心室收缩早期时最小(P均<0.05)。结论 MSCT肺静脉成像能准确、无创地提供肺静脉的解剖信息,有利于指导临床治疗。 Objective To quantitatively study the anatomic structure of pulmonary vein(PV) by MSCT venography(MSCTV).MethodTotally 500 patients who underwent 256-slice CT coronary artery and had negative results were retrospectively analyzed.The raw CT data and reconstructed PV images data were collected,then ventricular early diastolic and ventricular early systole phases were confirmed,the diameters of PV were measured,the types of anatomical variance of PV were calculated.ResultsThere were four types of pulmonary vein,type Ⅰ(443/500,88.60%),type Ⅱ(17/500,3.40%),type Ⅲ(4/500,0.80%),type Ⅳ(36/500,7.20%).The size and shape of PV varied during cardiac cycles.The maximal size of PV was generally at early diastolic phase,while the minimal size at ventricular early systole phase(P〈0.05).ConclusionMSCTV of pulmonary vein can noninvasively provide precise information of pulmonary vein anatomy,therefore guiding ablation and thoracic surgery.
出处 《中国医学影像技术》 CSCD 北大核心 2012年第7期1310-1313,共4页 Chinese Journal of Medical Imaging Technology
基金 河北省卫生厅重点科技研究计划(20110067)
关键词 肺静脉 解剖 心动周期 体层摄影术 X线计算机 Pulmonary veins Anatomy Cardiac cycle Tomography, X-ray computed
  • 相关文献

参考文献11

  • 1Marom EM, Herndon JE, Kim YH, et al. Variations in pulmo- nary venous drainage to the left atrium: Implications for radiofre- quency ablation. Radioligy, 2004,230(3) : 824 829.
  • 2Lacomis JM, Wigginton W, Fuhrman C, et al. Multi detector row CT of the left atrium and pulmonary veins before radio-fre- quency catheter ablation for atrial fibrillation. Radiographics, 2003,23 :S35 S48; discussion S48 -S50.
  • 3Ravenel JG, McAdams HP. Pulmonary venous infarction after radiofrequency ablation for atrial frbrillation. AJR Am J Ronent genol, 2002, 178(3) :664 666.
  • 4Cronin P, Kelly AM, Desjardins B, et al. Normative analysis of pulmonary vein drainage patterns on multidetector CT with meas urements of pulmonary vein ostial diameter and distance to first bifurcation. Aead Radiol, 2007,14(2) : 178 188.
  • 5Greil GF, Powell AJ, Gildein HP, et al. Gadolinium enhanced three-dimensional magnetic resonance angiography of pulmonary and systemic venous anomalies. J Am Coil Cardiol, 2002,39(2):335-341.
  • 6Yang M, Akbari H, Reddy GP, et al. Identification of pulmonary vein stenosis after radiofrequency ablation for atrial fibrillation u sing MRI. J Comput Assist Tomogr, 2001,25(1):34- 35.
  • 7单飞,张志勇,陈刚,缪熙音,刘豪,张利军,曾良斌.多排螺旋CT检测肺静脉变异及肺静脉孔指数在心房颤动射频消融术前的应用[J].中华心血管病杂志,2007,35(4):329-332. 被引量:5
  • 8Kluge A, Dill T, Ekinci O, et al. Decreased pulmonary perfusion in pulmonary vein stenosis after radiofrequency ablation: Assess ment with dynamic magnetic resonance perfusion imaging. Chest, 2004, 126(2):428 437.
  • 9Hauser TH, Yeon SB, Kissinger KV, et al. Variation in pulmo nary vein size during the cardiac cycle: Implications for non-elet roeardiogram-gated imaging. Am Heart J, 2006, 152 (5):974 e1-e6.
  • 10许尚文,成官迅,陈自谦,张雪林,曾建华,李天然,钱根年.重组相位窗对16层螺旋CT冠状动脉成像图像质量的影响[J].放射学实践,2006,21(3):250-254. 被引量:10

二级参考文献16

  • 1王照谦,杨志强,朱皓,周旭臣,郑晓群,曲新凯,方唯一,刘晓峰.16层CT冠状动脉成像双扇区图像重建算法与相位窗的优选[J].放射学实践,2005,20(3):199-201. 被引量:14
  • 2原珍团,余建群.肺静脉正常、变异及疾病的CT表现及其解剖病理基础[J].中国临床医学影像杂志,2005,16(9):520-523. 被引量:6
  • 3马长生,董建增,刘兴鹏.心房颤动的经导管消融治疗[J].中华心血管病杂志,2005,33(9):870-872. 被引量:10
  • 4Van Hoe L,Marchal G,Baert AL,et al.Determination of Scan Delay Time in Spiral CT-Angiography:Utility of a Test Bolus Injection[J].J Comput Assist Tomogr,1995,19(2):216-220.
  • 5Hong C,Becker CR,Huber A,et al.ECG-gated Reconstructed Multi-Detector Row CT Coronary Angiography:Effect of Varying Trigger Delay on Image Quality[J].Radiology,2001,220(3):712-717.
  • 6Windecker S,Maier-Rudolph W,Bonzel T,et al.Interventional Cardiology in Europe 1995[J].Eur Heart J,1999,20 (7):484-495.
  • 7Achenbach S,Giesler T,Ropers D,et al.Detection of Coronary Artery Stenoses by Contrast Enhanced,Retrospectively Electrocardiographically-gated,Multi-Slice Spiral Computed Tomorgaphy[J].Circulation,2001,103(21):2535-2538.
  • 8Lacomis JM, Wigginton W, Fuhrman C, et al. Multi-detector row CT of the left atrium and pulmonary veins before radio-frequency catheter ablation for atrial fibrillation. Radiographics, 2003, 23(Spee): S35-48.
  • 9Jongbloed MR, Dirksen MS, Bax JJ, et al. Atrial fibrillation:multi-detector row CT of pulmonary vein anatomy prior to radiofrequency catheter ablation-initial experience. Radiology,2005, 234(3) :702-709.
  • 10Cronin P, Sneider MB, Kazerooni EA, et al. MDCT of the left atrium and pulmonary veins in planning radiofrequency ablation for atrial fibrillation : a how-to guide. AJR Am J Roentgenol, 2004,183 (3) :767-778.

共引文献12