摘要
新老混凝土粘结是工程施工与老化病害结构修补补强中经常面临的一个问题。目前 ,人们对新老混凝土粘结的机理和力学性能还缺乏足够的了解 ,由于粘结面破坏造成的结构功能退化甚至工程事故也时有发生。鉴于此 ,在对影响新老混凝土粘结强度的因素进行试验研究的基础上 ,采用方差分析法对有关因素进行了分析 ,结果表明 ,粘结面的处理方式。
Binding of new and used concrete is a issue often facing to project implementation and old and poor structure maintenance. At present, there is no enough knowledge about the mechanism and mechanical characteristics of binding new and used concrete, and it is often happened that structure function get degenerated and even result to project disasters. In view of above mentioned facts, variance analysis method is applied to analyze relative factors on the basis of carrying out experimental study of factors influencing new and used concrete binding strength, the achievement shows that the treatment method, roughness of the binding surface and ratio of new concrete are of evident influence on binding strength.
出处
《人民黄河》
北大核心
2000年第4期31-33,共3页
Yellow River
基金
国家攀登计划(B)
国家自然科学基金资助项目
关键词
混凝土粘结
劈拉强度
抗折强度
粘结强度
concrete binding
splitting strength
flexure strength
variance analysis