Effects of acetabular morphology on contact mechanics of the hip joint
原文传递
导出
摘要 目的研究髋臼解剖几何形态对髋关节接触力学特性的影响。方法建立人体天然髋关节的解剖学模型以及具有不同髋臼外形的简化模型,利用有限元分析方法研究步态载荷作用下髋关节的接触力学行为。结果 (1)解剖学模型产生的接触主要在髋臼的中上部,沿身体前后方向分布,峰值接触应力出现在髋臼前上部。(2)与解剖学模型相比,旋转椭球形髋臼产生了类似的接触分布,而球形和旋转蚶线形髋臼产生的接触主要在髋臼中部,沿上下方向;(3)旋转椭球形髋臼具有最大的接触面积和最小的峰值接触压力和Von-Mises应力;(4)球形髋臼和旋转蚶线形髋臼具有类似的接触力学特征。结论与球形和旋转蚶线形相比,旋转椭球形能够更好地描述髋臼的解剖形态及其接触力学行为。 Objective To investigate the influence of acetabular morphology on contact mechanics of the human hip joint. Methods One anatomical finite element (FE) model of natural hip joint and three simplified FE models with different acetabular geometry were established to study the contact mechanics of hip joint under gait loads. Results ( 1 ) Contact predicted by the anatomical model was mainly distributed in the acetabuiar medial-superior area, from anterior to posterior, with the peak contact pressure occurred in the anterior-superior area; (2) Com- pared with the anatomical model, the rotational ellipsoid produced similar contact behavior, while the sphere and the rotational conchoids predicted that contact was distributed in the medial-lateral direction; (3) The rotational el- lipsoid predicted the largest contact area and the lowest peak contact pressure and Von-Mises stress; (4) The sphere and rotational conchoids had similar contact mechanical behavior. Conclusions Compared with the sphere and rotational conchoids, the rotational ellipsoid could be more preferable to represent the anatomical mor- phology of the acetabulum and its contact mechanics.
出处 《医用生物力学》 EI CAS CSCD 北大核心 2012年第3期264-269,共6页 Journal of Medical Biomechanics
基金 国家自然科学基金重大国际合作项目(30810103908) 江苏省普通高校研究生科研创新计划项目(CXZZ11_0287) 江苏高校优势学科建设工程资助项目
关键词 髋臼 解剖形态 有限元分析 力学特性 生物力学 Acetabulum Anatomical morphology Finite element analysis Mechanical properties Biomechanics
  • 相关文献

参考文献5

二级参考文献18

  • 1黄孝龙,葛世荣.人工关节置换材料——超高摩尔质量聚乙烯改性研究的进展[J].塑料工业,2006,34(11):1-3. 被引量:6
  • 2汪光晔,张春才,许硕贵,任可.标准步态下骨盆三维有限元模型构建及其生物力学意义[J].第四军医大学学报,2007,28(4):379-382. 被引量:13
  • 3Eric S. Stem,Mary I. O’Connor,Mark J. Kransdorf,Julia Crook. Computed tomography analysis of acetabular anteversion and abduction[J] 2006,Skeletal Radiology(6):385~389
  • 4S. Zilber,J.-Y. Lazennec,M. Gorin,G. Saillant. Variations of caudal, central, and cranial acetabular anteversion according to the tilt of the pelvis[J] 2004,Surgical and Radiologic Anatomy(6):462~465
  • 5Y. Miyanaga,T. Fukubayashi,H. Kurosawa. Contact study of the hip joint[J] 1984,Archives of Orthopaedic and Traumatic Surgery(1):13~17
  • 6Spears L R,Pfleiderer M,Schneider E,Hille E,Morlock M M.The effect of interfacial parameters on cup-bone relative micromotions: A finite element investigation[].Journal of Biomechanics.2001
  • 7Pyburn E,Goswami T.Finite element analysis of femoral components paper III: Hip joints[].Managerial and Decision Economics.2004
  • 8Yoshida H,Faust A,Wilckens J,Kitagawa M,Fetto J,Chao E Y.Three-dimensional dynamic hip contact area and pres- sure distribution during activities of daily living[].Journal of Biomechanics.2006
  • 9Scifert C F,Brown T D,Lipman J D.Finite element analysis of a novel design approach to resisting total hip dislocation[].Clinical Biomechanics.1999
  • 10Cheal E,Spector M,Hayes W.Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty[].Journal of Orthodontics.1992

共引文献43

同被引文献82

引证文献7

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部