药芯焊丝拉拔断裂原因分析

Fracture Analysis of Elongated Flux Cored Wire
在线阅读 下载PDF
导出
摘要 使用扫描电镜、能谱分析和背散射电子衍射等方法分析了药芯焊丝拉拔断裂的原因。结果表明,珠光体团中大块状渗碳体在拉拔过程中不易发生塑性变形,与基体脱离,形成裂纹源,裂纹在拉拔过程中快速扩展而导致焊丝最终断裂。 The fracture analysis of flux cored wire electron microscope ( SEM ), energy dispersive diffraction (EBSD). It was found that, due to its pearlites were easily broken up with the substrate, propagated Key Words during elongation was pertormed using scanning X-ray ( EDX ) and electron backscattered poor deformability, the big cementite blocks in where became the origins of cracks. The cracks quickly during the wire-drawing process and finally resulted in the fracturing
机构地区 首钢技术研究院
出处 《首钢科技》 2012年第3期40-42,54,共4页 Shougang Science and Technology
关键词 药芯焊丝 拉拔断裂 珠光体团 渗碳体 flux cored wire, fracture, pearlite, cementite
  • 相关文献

参考文献8

二级参考文献43

  • 1黄孝瑛 郭薇 潘天喜 赵坚.珠光体钢微观结构和断裂过程的TEM研究[J].金属学报,1987,23(3):200-200,204.
  • 2陈邦固.新一代高效环保焊接材料技术开发及产业化[R].2008.
  • 3钟群鹏 田永江.失效分析基础知识[M].北京:机械工业出版社,1990.201.
  • 4刘孝曾,于治水.药芯焊丝气孔倾向探讨[J].造船技术,1997,25(4):34-36. 被引量:4
  • 5唐伯钢.我国焊接材料世纪之交的发展前景与结构调整[A]..第九次全国焊接会议论文集[C].哈尔滨:黑龙江人民出版社,1999.96-102.
  • 6菅哲男.溶接材料[J].溶接学会志,1998,167(8):38-53.
  • 7桂赤斌.图表法选取船舶用钢焊接预热温度的适应性评价[J].兰州理工大学学报,2004,(30):167-168.
  • 8日本专利.JP04,300,091:水平すみ肉溶接用フラクス入りワイヤ[P].
  • 9美国专利UPS5,192,851:Cored Electrode Wire[P].
  • 10French I E,et al.Special Basic Flux Cored Wire For All-Position Pulsed Welding[J].Welding Journal,1997(3):120-124.