期刊文献+

对ASME Code Case N-494周向裂纹管失效评定曲线的评价 被引量:2

Evaluation of ASME Code Case N-494 Failure Assessment Curve Containing Circumferential Crack
在线阅读 下载PDF
导出
摘要 In N-494,by using specially defined L r as sbacissa, the scatter of FAC for piping containing circumferential crack is reduced compared to that using S r as sbacissa,especially for θ/π≤0 5.The N-494 FAC can assure the safety and reasonableness of assessment when θ/π≤0 5.But the applicable range for N-494 FAC is limited in θ/π≤0 5, otherwise the assessment accuracy is worse. Since the material stress-strain relationship used in N-494 is weaker than that of real material, so that the FAC is over conservative. Therefore, more accurate FAC for piping containing circumferential crack of any size should be developed. In N-494,by using specially defined L r as sbacissa, the scatter of FAC for piping containing circumferential crack is reduced compared to that using S r as sbacissa,especially for θ/π≤0 5.The N-494 FAC can assure the safety and reasonableness of assessment when θ/π≤0 5.But the applicable range for N-494 FAC is limited in θ/π≤0 5, otherwise the assessment accuracy is worse. Since the material stress-strain relationship used in N-494 is weaker than that of real material, so that the FAC is over conservative. Therefore, more accurate FAC for piping containing circumferential crack of any size should be developed.
机构地区 华东理工大学
出处 《压力容器》 2000年第2期50-56,共7页 Pressure Vessel Technology
基金 国家"九五"科技攻关项目资助
  • 相关文献

参考文献3

二级参考文献33

  • 1中国血管病变早期检测技术应用指南制订委员会.中国血管病变早期检测技术应用指南(第一次报告).中国民康医学杂志,2006,18(5):323-331.
  • 2Yan GX,Lankipalli RS,Burke JF,et al.Ventricular repolarization components on the electrocardiogram:cellular basis and clinical significance.J Am Coll Cardiol,2003,43:401-409.
  • 3Shinde R,Shinde S,Makhale C,et al.Occurrence of “J waves”in 122 lead ECG as a marker of acute ischemia and their cellular basis.Pacing Clin Electrophysiol,2007,30:817-819.
  • 4Yan GX,Ajay J,Duo DL,et al.Phase 2 reentry as a trigger to initiate ventricular fibrillation during early acute myocardial ischemia.Circulation,2004,110:1036-1041.
  • 5Shu J,Zhu T,Yang L,et al.ST segment elevation in the early repolarizati on syndrome,idiopathic ventricular fibrillation,and the Brugada syndrome:cellular and clinical llnkage. J Electrocardiol,2005,38:62.
  • 6Hlaing T,Di Mino T,Kowey PR,et al.ECG repolarization waves:their genesis and clinicalimp lications.Ann Noninvasive Electrocardiol,2005,10:211-223.
  • 7吴杰.心电图//陈文彬,潘祥林.诊断学.6版.北京:人民卫生出版社,2007:501.
  • 8郭继鸿.缺血性J波[J].临床心电学杂志,2007,16(4):298-305. 被引量:75
  • 9Tambe AA, Demany MA, Zimmerman HA, et al. Angina pectoris'and slow flow velocity of dye in coronary arteries: a new angiographic finding[J]. Am Heart J, 1972,84(1):66-71.
  • 10Mangieri E, Macchiarelli G, Ciavolella M, et al. Slow coronary flow: clinical and histopathological features in patents with otherwise normal epicardial coronary arteries[J]. Cathet Cardiovasc Diagn, 1996,37(4) :375-381.

共引文献38

同被引文献30

  • 1轩福贞,涂善东,王正东.基于TDFAD的高温缺陷"三级"评定方法[J].中国电机工程学报,2004,24(12):222-226. 被引量:8
  • 2李培宁,徐宏.ASME IWB—3650压力管道缺陷评定规范介绍[J].压力容器,1993,10(6):67-71. 被引量:21
  • 3徐宏,李培宁.防止起裂的压力管道缺陷断裂安全评定工程方法[J].石油化工设备,1995,24(3):14-18. 被引量:5
  • 4孟波,郭万林.V型缺口裂端的三维应力状态及约束分析[J].计算力学学报,2006,23(3):280-284. 被引量:6
  • 5American Petroleum Institute.Standard for welding pipelines and related facilities[S].API 1104 Sixteenth Edition,1983.
  • 6Kumar V,German M,Shih C.An engineering approach for elastic-plastic fracture analysis[R].EPRI Report NP-1931,Electric Power Research Institute,Palo Alto,CA,1981.
  • 7Kumar V,German M,Wilkening W,Andrews W.Advance in elastic-plastic fracture analyses[R].EPRI Final Report NP-3067,Electric Power Research Institute,Palo Alto,CA,1984.
  • 8Paris P C Tada H.The application of fracture proof design methods using tearing instability theory to nuclear piping postulating circumferential through-wall cracks[R].NUREG/CR-3464,1983.
  • 9Klecker R,Brust F,Wilkowski G M.NRC leak-before-break(LBB-NRC)analysis method for circumferentially through-wall cracked pipes under axial plusb ending loads[R].NUREG/CR-4572,1986.
  • 10Lejeail Y,Gaillard J P.Feasibility study on the application of a leak before break procedure in metallic vessels of a fast neutron gas cooled reactor[R].CEA Technical note,2002.

引证文献2

二级引证文献37