摘要
基于M.Hanss的初始流量法原理,本文提出了一种改进的测量红细胞变形能力的核孔膜滤过技术:上升引流液的光电计时法。具有测时精确,重复性好等优点,已初步用于临床研究。
<ABSTRACT>
According to the principle of initial flow rate method, an improved
filtration technique for measurement of erythrocyte deformability using
nucleopore filter is presented as optic-electric chronometry of rising liquid
(Continued on page 77 )
(Continued from page 72 )
drainage. The method have the merits of high precision in time measurem-
ent and fine reproducibility. The apparatus has been initially used in
clinical research.
出处
《中国生物医学工程学报》
CAS
CSCD
北大核心
1990年第2期69-72,77,共5页
Chinese Journal of Biomedical Engineering