介绍对柳钢炼铁厂1、2号高炉2间助燃风机房和1间排粉风机房实施的吸声、隔声、通风消声等综合降噪治理措施及其效果。
The comprehensive noise control measures and it effects, such as the sound absorption, the acoustic insulation and the noise elimination by ventalation applied in two combusion fan houses one dedusting fan house of No. 1 and 2 Blast Furnace in Iromaking Plant of Liuzhou Steel were introduced.
关键词
风机房
噪声
降噪
吸声
隔声
通风消声
Fan House
Noise
Noise Control
Sound Absorption
Acoustic Insulation
Noise E-limination by Ventalation