期刊文献+

超高效液相色谱法测定四乙酰葛根素的含量及有关物质

UPLC determination of the content and related substances of tetra-acetylated puerarin
原文传递
导出
摘要 目的建立测定四乙酰葛根素的含量及有关物质的超高效液相色谱法。方法采用Agilent XDB-C18色谱柱(4.6mm×250mm,5μm),流动相:乙腈-水(45∶55),流速:1.2 mL.min-1,检测波长:250nm,柱温:30℃。结果四乙酰葛根素的浓度在0.020 76~0.186 8mg.mL-1与峰面积线性关系良好(A=1.287×104 C-24.55,r=0.999 9,n=7),检测限为6.65ng.mL-1(S/N=3);平均加样回收率为99.9%(RSD=1.4%,n=9);有关物质含量为1.02%~1.28%。结论该方法简便、准确,可用于四乙酰葛根素的含量及有关物质的测定。 Objective To establish a UPLC method to determine the content and related substances of tetra-acetylated puerarin.Methods Agilent XDB-C18 chromatographic column(4.6 mm×250 mm,5 μm)was used and the mobile phase consisted of acetonitrile-water(45∶55)with a flow rate of 1.2 mL·min-1.The UV detection wavelength was 250 nm.The column temperature was 30 ℃.Results The calibration curve was linear over 0.020 76-0.186 8 mg·mL-1(A=1.287×104C-24.55,r=0.999 9,n=7).The detection limit was 6.65 ng·mL-1(S/N=3).The average recovery was 99.9%(RSD=1.4%,n=9).The content of related substances of tetra-acetylated puerarin was over 1.02%-1.28%.Conclusion The method is simple,accurate,and applicable for the quality control of tetra-acetylated puerarin.
出处 《中南药学》 CAS 2012年第3期196-198,共3页 Central South Pharmacy
基金 国家科技部重大专项项目(No.2009ZX09103-150)
关键词 四乙酰葛根素 超高效液相色谱法 含量测定 有关物质 tetra-acetylated puerarin UPLC content determination related substance