期刊文献+

The Protection against Lightning of an Overhead Line Uprated from 225 kV to 400 kV 被引量:1

The Protection against Lightning of an Overhead Line Uprated from 225 kV to 400 kV
在线阅读 下载PDF
导出
摘要 The voltage uprating of existing overhead lines is an interesting solution for increasing the transmission of electricity, especially in areas where it is difficult to build new lines. If a line is uprated with minor changes of its design and without improvement of the grounding electrodes of towers, its lightning performance remains unchanged. The consequence is that the uprated line will have a lightning flashover rate very high compared to an overhead line of same nominal voltage but of standard design. One attractive solution to solve this problem is to use line arresters. The goal of this paper is to study the use of line arresters to achieve a satisfactory lightning performance of an overhead line uprated from 225 kV to 400 kV without major design modifications. In order to compare different strategies of line arrester installation the flashover rate is calculated based on a software able to launch automatically EMTP-RV. The software named LIPS has been developed under the cover of a partnership between Hydro-Quebec, RTE and EDF.
出处 《Journal of Energy and Power Engineering》 2012年第2期267-275,共9页 能源与动力工程(美国大卫英文)
关键词 LIGHTNING transmission line voltage uprating insulation coordination. 输电线路 大功率 防雷保护 线路避雷器 架空线路 防雷性能 雷击闪络 标准设计
  • 相关文献

参考文献18

  • 1P. Pramayon, P. Catchpole, S. Guerard, N. Norton, R. Puffer, A. Sorensen, Increasing capacities of overhead lines needs and solutions, in: Paris General CIGRE Conference, France, 2008.
  • 2CIGRE study committee B2, Conductors for the uprating of overhead lines, Technical brochure 244, CIGRE, Paris, 2004.
  • 3L.0. Bathold, D.A. Douglass, D.A. Woodford, Maximizing the capability of existing AC transmissionlines, in: Paris General CIGRE Conference, France, 2008.
  • 4CIGRE study committee B2, Considerations relating to the use of high temperature conductors, Technical brochure 331, CIGRE, Paris, 2007.
  • 5Electric Power Research Institute, Transmission Line Reference Book-115-138 kV Compact Line Design, EPRI, Palo Alto, 1978.
  • 6CIGRE, Compacting overhead transmission lines, in: Symposium C1GRE, Leningrad, Russia, 1991.
  • 7K. Halsan, D. Loudon, I. Gutman, J. Lundquist, Feasibility of upgrading 300 kV AC lines to DC for increased power transmission capability, in: Paris General CIGRE Conference, France, 2008.
  • 8IEC, Insulation Coordination Part 2, Application Guide, Standard 60071.2, IEC, Geneva, 1996.
  • 9CENELEC, Overhead lines exceeding AC 45 kV, Part 1 : General requirements-common specifications, Standard EN 50341, CENELEC, Brussels, 2001.
  • 10J. Mahesredjian, S. Denneti6re, L. Dub6, B. Khodabakhchian, G. Lajoie, On a new approach for the simulation of transients in power systems, in: International Conference on Power System Transients, Montreal, Canada, 2005.

同被引文献4