摘要
主要介绍了在M701F燃气轮机联合循环机组两班制调峰运行,机组每日启停并承担腰荷和峰荷的情况下,电厂辅机变频运行的相关情况,并在系统的设计、设备的选型及运行方式等方面都进行了优化,降低了厂用电率和气耗率,取得了很好的安全可靠性和经济效益,对同类型机组具有较好的参考价值。
In view of M701F gas turbine combined cycle power plant in two-shift peaking unit operating, start-stop and taking back the daily load and peak load, the unit are designed to run auxiliary inverter. And system design, equipment selection and operation mode are optimized to reduce the power consumption rate and gas consumption rate, which made a very good safety and reliability and eco- nomic benefits. The same type of unit has a good reference value.
出处
《燃气轮机技术》
2012年第1期67-72,共6页
Gas Turbine Technology
关键词
辅机
变频器
变频运行
节电量
节电率
auxiliary equipment
frequency converter
frequency operation
electricity saving