期刊文献+

三相四开关并联型有源电力滤波器关键参数计算及其实现 被引量:2

Key Parameters Calculation and Implementation of Three-Phase Four-Switch Shunt Active Power Filter
在线阅读 下载PDF
导出
摘要 为减少电力系统中的谐波与无功功率污染问题,提高电能的有效利用率,设计了一种经济性的三相四开关并联型有源电力滤波器。阐述了三相四开关并联型有源电力滤波器主电路关键参数的计算方法,分析了有源电力滤波器的主电路拓扑结构、控制系统硬件原理及算法的软件实现流程。现场工程应用案例证明了该系统的可行性和有效性。 To reduce the harmonics and reactive power pollution and improve the effective utilization of ener- gy, a low-cost three-phase four-switch shunt active power filter was proposed. Key parameters calculation of three- phase four-switch shunt active power filter was presented. The topology structure of main circuit, the principles of the control system and the flow of the control software were described. The application in industrial site proves its feasibility and validity.
出处 《低压电器》 2012年第3期53-57,共5页 Low Voltage Apparatus
关键词 有源电力滤波器 并联型 三相四开关 无功补偿 shunt active power filter(APF) three-phase four.switch reactive power compensation