期刊文献+

含铝炸药中铝粉活性的光谱法测试研究 被引量:3

Determination of Aluminium Powder Activation in Aluminized Explosives by Spectrometry
在线阅读 下载PDF
导出
摘要 为评价含铝炸药中铝粉的活性,用X荧光(XRF)光谱法、X衍射(XRD)光谱法测定了FLX、FLU系列中铝粉的活性。结果表明,仅XRF可以用于铝粉活性的分析。铝粉活性测试校正系数由拟合XRF法与标准方法GJB1738-1993的结果得到。XRF法和标准方法GJB1738-1993所得A-Ⅸ-Ⅱ炸药中铝粉活性结果的相对测量误差≤4%。 In order to evaluate the activation of aluminium powder in aluminized explosives,the activity of aluminium powder in military FLX and FLU series was measured by X-ray fluorescence (XRF) spectrometry and X-ray diffraction (XRD) spectrometry. The results show that only XRF method can be used to analyze activity of aluminium powder. A correction factor of aluminium activity is obtained by fitting results of XRF method and standardization method ( chemical analysis method) GJB1738 - 1993. The relative deviation obtained by XRF method and chemical analysis method for detecting activity of aluminium powder in A-Ⅸ-Ⅱ explosives is less than 4%.
出处 《含能材料》 EI CAS CSCD 北大核心 2012年第1期94-98,共5页 Chinese Journal of Energetic Materials
基金 火炸药行业青年基金(项目号:42001060401)
关键词 分析化学 光谱分析 铝粉活性 含铝炸药 analytical chemistry spectrometry active aluminium powder aluminized explosive