期刊文献+

CT引导下应用单次弹射活检针经皮肺活检58例临床分析 被引量:3

Under the Guidance of CT Application Single Ejection Biopsy Needle Percutaneous Lung Biopsy Clinical Analysis of 58 Cases
暂未订购
导出
摘要 目的:探讨在CT引导下应用单次弹射活检针经皮肺穿刺活检的临床应用有效性及安全性。方法:选取我科2007年3月至2010年12月未明确诊断的肺部周围型结节或肿块58例患者,应用单次弹射活检针在CT引导下经皮肺穿刺获取病理标本。结果:全部病例均获得病理标本,穿刺成功率100%,明确诊断57例。其中肺癌49例,结核5例,炎性假瘤3例,报告坏死组织1例。结论:在CT引导下应用单次弹射活检针行经皮肺穿刺活检是安全有效。 Objective: to discuss the application in CT guided single ejection biopsy needle percutaneous lung puncture biopsy in the clinical application of effectiveness and safety. Methods: from March to 2010, December, 2007 1 not clear diagnosis of peripheral pulmonary nodules or masses in 58 cases of patients with single ejection biopsy needle in CT guided percutaneous lung biopsy for pathologic specimens. Results: all cases were obtained in pathological specimens, puncture success rate 100%, definite diagnosis in 57 cases. One of the lung in 49 cases, 5 cases of tuberculosis, 3 cases inflammatory pseudotumor, report of necrotic tissue in l cases. Conclusion: under the CT guidance application single ejection biopsy needle percutaneous lung biopsy is safe and effective.
出处 《中国医药导刊》 2011年第9期1629-1630,共2页 Chinese Journal of Medicinal Guide
关键词 单次弹射活检针 肺穿刺 病理诊断 Single ejection biopsy needle lung aspiration Pathological diagnosis
  • 相关文献

参考文献4

二级参考文献15

  • 1张雪哲,曲凤宏.CT导引下胸部经皮细针穿刺活检的临床应用[J].中华放射学杂志,1989,23(1):47-48. 被引量:86
  • 2Li H, Boiselle PM, Shepard JO, Trotman-Dickenson B, McCloud TC. Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR, 1996.
  • 3Kazerooni EA, Lim FT, Mikhail A, Martinez FJ. Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. Radiology, 1996,198:371 - 375.
  • 4Joseph E. Cox, MD, Caroline Chiles, MD, Christopher M. McManus, MD,et al. Transthoracic Needle Aspiration Biopsy: Variables That Affect Risk of Pneumothorax. Radiology, 1999,212 : 165 - 168.
  • 5Yeon KM PK,Cheang Yc,Fuctors affterting diagnostic acauracy of CT-guided Coaxial Cutting needle Lung biopsy;retrospective analysis of 631 procedures[J].Jvasc interv Radiol,2003,12:5.
  • 6Westcott J L,Radiology,1996年,201卷,270页
  • 7张雪哲,CT介入放射学,1996年,15页
  • 8Zhang Xuezhe,Chin Med J,1990年,103卷,599页
  • 9张雪哲,中华放射学杂志,1989年,23卷,47页
  • 10卢金山,何杰.CT引导下胸部病变穿刺活检的临床应用[J].实用放射学杂志,2008,24(3):424-425. 被引量:8

共引文献317

同被引文献12

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部