期刊文献+

穿刺引导架在CT介入治疗中的应用 被引量:15

Application of a puncture guidance supporter in CT intervention
暂未订购
导出
摘要 目的探讨穿刺引导架在CT导向活检和介入治疗中的应用。方法对468例患者应用穿刺引导架行CT引导介入活检或治疗,其中110例接受穿刺活检,358例接受穿刺治疗;胸部病变192例,腹部病变276例,病灶大小2~15cm。穿刺前行CT薄层扫描确定皮肤进针点、确定双向进针角度α、θ和深度d等数据,放置穿刺引导架,局麻后将穿刺针刺人皮肤,调整穿刺针体与CT机架(α)定位激光线重合,穿刺角度为θ。CT扫描确认穿刺针瞄准病灶靶点,将穿刺针刺入至进针深度,命中靶点。结果总体穿刺命中率为100%,一步命中率为96.79%,定位扫描开始至穿刺命中平均8.4min;胸部穿刺气胸发生率为1.56%。结论穿刺引导架应用于CT介入诊疗,使操作准确、安全、便捷,值得推广。 Objective To evaluate the application of a puncture guidance supporter in CT guided biopsy and interventional therapy. Methods Totally 468 patients underwent CT interventional biopsy (n=10) or treatment (n=358) using a puncture guidance supporter. The size of lesions was 2 15 cm. CT scanning was performed to determine the entry point, data of bi-directional needle angle a, 0 and depth d before operation. After local anesthesia, the needle was punctured into skin through the puncture guidance supporter, the needle overlap CT positioning laser line in tilt angle (a) was adjusted and the puncture direction at angle 0. After CT scanning confirmed the needle aiming at target lesion, punctures were performed with the needle into the depth to hit the target. Results The total puncture hit rate was 100%, and one step hit rate was 96.79%. The average time from location scanning to hit the target was 8.4 min. The incidence of pneumothorax occurred in thorax management was 1.56%. Conclusion The application of puncture guidance supporter in CT interventional diag nosis and treatment makes operation more accurate, safe and convenient.
出处 《中国介入影像与治疗学》 CSCD 2010年第1期66-69,共4页 Chinese Journal of Interventional Imaging and Therapy
关键词 体层摄影术 X线计算机 放射学 介入性 穿刺引导架 Tomography, X-ray computed Radiology, interventional Puncture guidance supporter
  • 相关文献

参考文献10

二级参考文献18

  • 1商健彪,刘方颖,李彦豪,裴著果.^(18)F-FDG PET、CT和血管造影在原发性肝癌TACE后随访的对比研究[J].中国临床医学影像杂志,2004,15(9):509-512. 被引量:13
  • 2董其龙,李达志,李天然,赖国祥,宋均娜.肺部周围型肿块CT引导下经皮穿刺活检病理对照研究[J].介入放射学杂志,2004,13(6):544-545. 被引量:19
  • 3何文,梁晓宁,张晓蓉,姜晓红,郑永才,张颖.超声引导微波联合肝动脉化疗栓塞术治疗大肝癌的疗效评价[J].中国微创外科杂志,2005,5(1):31-33. 被引量:22
  • 4[8]Charig M J,Phillips A J. CT-guided cutting needle biopsy of lung lesions-safety and efficacy of an out-patient service[J]. Clin Radiol,2000 Dec,55(12):964-969.
  • 5[9]Law E M, Little A F, Salanitri J C. Non-vascular intervention with real-time CT fluoroscopy[J]. Australasian Radiology,(2001)45,109-112.
  • 6[1]Gerzof S, Robbins A H, Johnson W C,et al. Percutaneous catheter drainage of abdominal abscesses: a five year experience[J]. N Engl J Med,1981,305(12):653-657.
  • 7[2]Olak J, Christou N V, Stein L A, et al. Operative vs. percutaneous drainage of intra-abdominal abscesses: comparison of morbidity and mortality[J]. Arch Surg,1986,121(2):141-146.
  • 8[3]Hemming A, Davis N L, Robins R E. et al. Percutaneous drainage of intra-abdominal abscesses[J]. Am J Surg,1991,161(5):593-595.
  • 9[4]Gerzof S G, Johnson W C, Robbins A H, et al. Expanded criteria for percutaneous abscess drainage[J]. Arch Surg,1985,120(2):227-232.
  • 10[5]vanSonnenberg E, Mueller P R, Ferrucci J T. Percutaneous drainage of 250 abdominal abscesses and fluid collections. Part I; results failures and complications[J]. Radiology,1984,151(2):337-341.

共引文献51

同被引文献122

引证文献15

二级引证文献63

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部