摘要 针对两种仪器化压入仪和两种代表性压入测试方法:Oliver-Pharr方法和Ma方法,通过有限元数值模拟分析了仪器柔度标定误差对2种仪器和两种方法测试精度的影响。结果表明仪器柔度的标定精度直接影响压入测试结果的准确度,仪器柔度越小,测试精度越高;就测试方法而言,Ma方法具有比Oliver-Pharr方法更高的精度和更低的仪器柔度敏感性;对同一材料,压入深度越大,由仪器柔度标定误差引入的压入测试结果误差越大;当材料较硬且压入深度较大时仪器柔度的标定尤为重要,小量的标定误差导致测试结果严重偏离真值,甚至为负值。 Effect of machine compliance calibration errors on test accuracy are studied by means of finite element analysis using two kinds of instrumented indentation equipment and two representative indentation test methods: Oliver-Pharr method and Ma method. Results show that the test accuracy is directly influenced by the accuracy of machine compliance calibration errors; the smaller the machine compliance is, the higher the test accuracy is. In terms of test methods, Ma method has higher accuracy and lower sensitivity of machine compliance compared with Oliver- Pharr method. For the same material, the deeper the indentation depth is, the greater the test errors caused by compliance calibration errors are. When the material is harder and the indentation depth is deeper, machine compliance calibration is more important. A compliance calibration error of small value will lead to big windage between the test result and the real value; even the test result becomes negative.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2011年第9期2095-2100,共6页 Chinese Journal of Scientific Instrument
基金 国家自然科学基金(No.10672185)资助项目
关键词 仪器化压入 柔度 标定误差 弹性模量 instrumented indentation compliance calibration error elastic modulus
  • 相关文献

参考文献17

  • 1CHENG Y T, PAGE T, PHARR G M, et al. Fundamen- tals and applications of instrumented indentation in muhi- disciplinary research [ J ]. Journal of Materials Research, 2004,19(1) :1-2.
  • 2ISO 14577. Metallic Materials-Instrumented Indentation Test for Hardness and Materials Parameter[ S].
  • 3徐临燕,栗大超,刘瑞鹏,傅星,张文栋,胡小唐.基于AFM的纳米梁杨氏模量和残余应力测量[J].仪器仪表学报,2010,31(1):201-207. 被引量:8
  • 4朱守星,丁建宁,范真,蔡兰.用AFM压痕技术定量介观硬度的方法研究[J].仪器仪表学报,2005,26(3):272-274. 被引量:3
  • 5OLIVER W C, PHARR G M. An improved technique for determining hardness and elastic-modulus using load and displacement sensing indentation experiments[J]. J. Ma- ter. Res. , 1992,7 (6) : 1564-1583.
  • 6OLIVER W C, PHARR G M. Measurement of hardness and elastic modulus by instrumented indentation: Ad- vances in understanding and refinements to methodology [J]. J. Mater. Res., 2004,19(1):3-20.
  • 7MA D J, ONG C W, ZHANG T H. An improved energy method for determining young's modulus by instrumented indentation using a berkovich tip[ J]. Journal of Materials Research, 2008, 23(8): 2106-2115.
  • 8周向阳,蒋庄德,王海容.压入测试仪柔度标定方法研究[J].仪器仪表学报,2007,28(1):85-89. 被引量:7
  • 9ULLNER CH, REIMANN E, KOHLHOFF H, et al. Effect and measurement of the machine compliance in the macro range of instrumented indentation [ J ]. Meas- urement,2010,43 ( 3 ) :212-216.
  • 10VLIET K J, PRCHLIK L, SMITH J F. Direct measure- ment of indentation frame compliance [ J ]. J. Mater. Res. ,2004,19( 1 ) :325-331.

二级参考文献46

  • 1朱守星,丁建宁,范真,蔡兰.用AFM压痕技术定量介观硬度的方法研究[J].仪器仪表学报,2005,26(3):272-274. 被引量:3
  • 2熊继军,张文栋,薛晨阳,桑胜波,周兆英.拉曼光谱应用于硅微悬臂梁的应力特性测试[J].中国机械工程,2005,16(14):1292-1295. 被引量:6
  • 3韩光平,刘凯,王秀红.单晶硅微桥式梁力学性能的弯曲测试[J].仪器仪表学报,2006,27(2):176-179. 被引量:5
  • 4BINNING G, ROHRER H. Scanning tunneling microscopy[J]. Helv. Phys. Acta, 1982, 55(6): 726-725.
  • 5BINNING G, QUATE C F, GERBER C. Atomic force microscopy[J]. Phys. Rev. Lett, 1986, 56: 930-933.
  • 6GARCIA R, PEREZ R. Dynamic atomic force microscopy methods[ J]. Surface Science Reports, 2002 : 105.
  • 7KELLER D J, FRANKE F S. Envelope reconstruction of probe microscope images [ J ]. Surface Science, 1993, (294) : 11.
  • 8VILLARRUBIA J S. Morphological estimation of tip geometry for scanned probe microscopy [ J ]. Surf. Sci, 1994, 321(3) : 287-300.
  • 9KELLER D. Reconstruction of STM and AFM images distorted by finite-size tips [ J]. Surface Science, 1991, 253 : 353-364.
  • 10MONTELIUS L, TEGENFELDT J O. Direct observation of the tip shape in scanning probe microscopy [ J ]. Applied Physics Letters, 1993, 62(21) : 3.

共引文献37

同被引文献19

  • 1丁建宁,孟永钢,温诗铸.纳米硬度计研究多晶硅微悬臂梁的弹性模量[J].仪器仪表学报,2001,22(2):186-189. 被引量:8
  • 2周向阳,蒋庄德,王海容.压入测试仪柔度标定方法研究[J].仪器仪表学报,2007,28(1):85-89. 被引量:7
  • 3蒋庄德,王海容,赵则祥,等.微机械力学性能测试仪:中国,00226180[P].2000-12-29.
  • 4PHARR G M,CHENG Y T,HUTCHINGS I M,et al.Indentation methods in advanced materials research[J].J.Mater.Res.,2009,24 (3):579-580.
  • 5ISO14577.Metallic materials-instrumented indentation rest for hardness and materials parameter[S].
  • 6刘海军,何家文,苏启生,等.亚微压入仪:中国,CN2175934[P].1994-08-31.
  • 7赵宏伟,黄虎,曲兴田,等.微纳米级原位纳米压痕刻划测试系统:中国,201010121060.0[P].2010-11-03.
  • 8姜辛,张泰华,郇勇,等.一种便携式压入仪:中国,200820080577.8[P].2009-02-04.
  • 9马德军,宋仲康,郭俊宏,等.一种高精度仪器化压入仪及金刚石压头压入试样深度的计算方法:中国,201110118464.9[P].2011-12-21.
  • 10马德军.仪器化微米压入测试材料杨氏模量的方法:中国,200910241216.6[P].2010-05-19.