期刊文献+

科氏流量计应用于气液两相流测量的实验研究 被引量:2

Experimental Study on Gas-liquid Two Phase Flow Measurement Using Coriolis Flowmeter
在线阅读 下载PDF
导出
摘要 以空气-水为介质,对科氏流量计应用于气液两相流双参数测量进行了实验研究。实验过程中保持液相流量一定,通过加入不同体积分数的空气来分析含气率对科氏流量计测量精度的影响,采用Weisman垂直上升管气液两相流流型图与实验数据进行了比较。结合实验结果,初步归纳出含气量、流型和科氏流量计测量精度之间的关系,总结出液相中含气影响科氏流量计测量精度的主要因素及其影响规律,为进一步研究科氏流量计气液两相流测量误差修正提供了一种技术方法。 Two parametric measurement of gas-liquid two-phase flow based on Coriolis mass flowmeter was studied.In the experiment,liquid flow was maintained at a fixed value,experimental data were collected under different gas void fraction.According to Weisman vertical upward gas-liquid flow pattern maps,the flow pattern of gas-liquid two-phase flow in the tube was analyzed.Combining with experimental results,the relationship among gas volume fraction,flow pattern and Coriolis flowmeter measurement accuracy was summed up,the main influence factor on the Coriolis flowmeter measurement accuracy due to the presence of aeration and its influence rules were summarized,which provided a new method for further study on gas-liquid two-phase flow measurement error correction using Coriolis flowmeter.
出处 《仪表技术与传感器》 CSCD 北大核心 2011年第3期25-27,43,共4页 Instrument Technique and Sensor
基金 国家"863"高技术发展计划项目(2008AA042207) 中央高校基本科研业务费专项资金(09CX04047A) 山东省自然科学基金青年基金项目(ZR2010EQ015)
关键词 科氏质量流量计 流量 气液两相流 流型 体积含气率 coriolis mass flowmeter flow gas-liquid two phase flow flow pattern gas volume fraction
  • 相关文献

参考文献9

  • 1DUTTON R E. Correction of coriolis flowmeter measurements due to multiphase flows. US Patent: RE40,095,2008 - 02 - 26.
  • 2刘磊,胡志华,周芳德.利用振动管的科氏力与谐振特性两相流测量.中国工程热物理学会多相流学术会议,大连,2002.
  • 3纪爱敏,李川奇,沈连官,尹协振.科里奥利质量流量计研究现状及发展趋势(二)[J].仪表技术与传感器,2001(7):1-2. 被引量:7
  • 4ttENRY M P,De La FUENTE M J. Correcting for two-phase flow in a digital flowmeter. US Patent :6,918,424,2006 - 01 - 03.
  • 5HENRY M P, CLARKE D W,ARCHER N, et al. A self-validating dig- ital Coriolis mass-flow meter: an overview. Control Engineering Practice,2000,8 (5) :487 - 506.
  • 6LIU R P,FUENT M J,HENRY M P,et al. A neural network to correct mass flow errors caused by two-phase flow in a digital coriolis mass flowmeter. Flow Measurement and Instrumentation,2001, (12):53 - 63.
  • 7HEMP J,YEUNG H. Coriolis meters in two phase conditions. Computer & Control Engineering,2003,14 (4) :36.
  • 8SKEA A F, HALL A R W. Effects of gas leaks in oil flow on single- phase flowmeters. Flow Measurement and Instrumentation, 1999,10: 145 - 150.
  • 9WEISMAN J, KANG S Y. Flow pattern transitions in vertical and upwardly incling line. Multiphase Flow, 1981,7 : 271 - 291.

二级参考文献20