常闭式触发开关失效分析及预防措施 被引量:5

Failure Analysis and Preventive Measures of Normally Closed Trigger Switch
在线阅读 下载PDF
导出
摘要 触发开关是触发引信的主要部件。某触发开关装配到整机后在振动试验中出现早炸故障。通过金相检验和能谱分析等方法对触发开关的失效原因进行了分析。结果表明:触发开关印制板镀钯层存在缺陷,开关内存在异物导致了接触电阻异常的故障。并且通过试验确定了合理的镀金层厚度,结合实际完善了触发开关制造工艺过程,制定了预防触发开关失效的综合控制措施。 Trigger switch is the main part of trigger fuse. A trigger switch was assembled to the trigger fuse, which brought misacting before the normal bomb time in vibration test. The failure reason was analyzed by means of metallographic examination and energy spectrum analysis. The results showed that the main reasons were cladding material defects and unexpected existence. The reasonable thickness of gold layer and better process were promoted, and the comprehensive control measures for avoiding the trigger switch failure were given.
出处 《理化检验(物理分册)》 CAS 2011年第7期447-450,共4页 Physical Testing and Chemical Analysis(Part A:Physical Testing)
关键词 触发开关 镀层 接触电阻 磨损 trigger switch cladding touch resistance wear
  • 相关文献

参考文献2

  • 1袁正,孙志杰.空空导弹引战系统设计[M].北京:国防工业出版社,2007.
  • 2梁棠文.防空导弹引信设计及仿真技术[M].北京:宇航出版社,1995.

共引文献41

同被引文献31

引证文献5

二级引证文献2

相关作者