期刊文献+

带LC滤波的三相逆变器的比例谐振控制 被引量:14

Proportinal-resonant Control for Three-phase Inverter with LC Filters
在线阅读 下载PDF
导出
摘要 针对带LC输出滤波器的三相电压型逆变器,提出一种新的无电流传感器比例谐振(PR)控制策略,仅需检测输出滤波电容电压,无需检测其电流。相比于同步旋转坐标系的PR控制器,提出的PR控制器基于静止坐标系,无需进行复杂的坐标变换,减少了计算量,能对正序与负序电流进行统一调节。仿真和实验结果表明,该控制策略具有良好的动静态性能,可实现正弦交流指令的零稳态误差控制,利用其谐振控制器的特性对特定次谐波进行补偿,在逆变器带平衡负载和不平衡非线性负载时都能适用。 A novel current sensorless proportional-resonant(PR) control scheme for three-phase inverter with LC output filters is presented.The proposed control scheme with use of current sensorless only requies voltage measured across capacity instead of current measured.Compared with PR controller in synchronous frame,the proposed PR controller is implemented in stationary frame without complex reference frame transforms,it is able to adjust positive and negative sequence components of the output current simultaneously.Simulation and experimental results show that the control scheme has good dynamic and static performances,the proposed scheme can achieve zero steady-state error for sinusoidal reference command,specific harmonics can be compensated by use of the resonant characteristics of the controller,the controlled inverter can operate well in blance loads or nonlinear unbalance loads.
出处 《电力电子技术》 CSCD 北大核心 2011年第6期76-78,共3页 Power Electronics
基金 湖南省2010年科技计划项目(2010GK3100) 湖南省2009年高校创新平台开放基金项目(2009K100)~~
关键词 逆变器 比例谐振控制 滤波 inverter proportinal-resonant control filting
  • 相关文献

参考文献6

  • 1HU Jiabing,HE Yikang,XU L,et al.Improved Control of DFIG Systems During Network Unbalance Using PI2R Current Regulators[J].IEEE Trans. on Industrial Electronics, 2009,56 (2) : 439-451.
  • 2李辉,廖勇,姚骏,庄凯.不平衡电网电压下基于串联网侧变换器的DFIG控制策略[J].电力系统自动化,2010,34(3):96-100. 被引量:13
  • 3D N Zmood, D G Holmes.Stationary Frame Current Regulation of PWM Inverters with Zero Steady-state Error[J]. IEEE Trans. on Power Electronics, 2003,18 ( 3 ) : 5-62.
  • 4R Teodorescu, F Blaabjerg, M Liserre, e.t al.Proportional- resonant Controllers and Filters for Grid-connected Voltage-source Converters[J].IEEE Pros. Electr. Power Appl., 2006,153 (5) : 158-169.
  • 5王继东,朱雪玲,苏海滨,王玲花.三相光伏并网Z-源逆变器的比例谐振控制[J].电机与控制学报,2010,14(4):86-91. 被引量:42
  • 6M Liserre, R Teodorescu, F Blaabjerg.Multiple Harmonics Control for Three-phase Grid Converter Systems with the Use of PI-RES Current Controller in a Rotating Frame[J].IEEE Trans. on Power Electronics, 2006,21 (3) : 96-104.

二级参考文献24

  • 1胡家兵,贺益康,郭晓明,年珩.不平衡电压下双馈异步风力发电系统的建模与控制[J].电力系统自动化,2007,31(14):47-56. 被引量:91
  • 2PIWKO R, MILLER N, GASCA J S, et al. Integrating large wind farms into weak power grids with long transmission lines// Proceedings of IEEE Power Electronics and Motion Control Conference: Vol 2, August 14-16, 2006, Shanghai, China: 1-7.
  • 3MULJADI E, YILDIRIM D, BATAN T, et al. Understanding the unbalanced-voltage problem in wind turbine generation// Proceedings of the 34th Industry Applications Society Annual Meeting: Vol 2, October 3-7, 1999, Phoenix, AZ, USA: 1359-1365.
  • 4NAESS B I, UNDELAND T M, GJENGEDAL T. Methods for reduction of voltage unbalance in weak grids connected to wind plants// Proceedings of IEEE Workshop Wind Power Impacts Power System, June 17-18, 2002, Oslo, Norway: 1-7.
  • 5BREKKEN T, MOHAN N. Control of a doubly fed induction wind generator under unbalanced grid voltage conditions. IEEE Trans on Energy Conversion, 2007, 22(1): 129-135.
  • 6WANG Hungsheng, ZHANG Wei, HU Jiabing, et al. Design and optimization of proportional resonant controller for rotor current of a wind turbine driven DFIG//Proceedings of the llth International Conference on Electrical Machines and Systems, October 17-20, 2008, Wuhan,China: 2502 2506.
  • 7HU Jiabing, HE Yikang, XU L, et al. Improved control of DFIG systems during network unbalance using PI-R current regulators. IEEE Trans on Industrial Electronics, 2009, 56(2): 439-451.
  • 8ZHOU Y, BAUER P, FERREIRA J A. Operation of grid- connected DFIG under unbalanced grid voltage condition. IEEE Trans on Energy Conversion, 2009, 24(1): 240-246.
  • 9HE Yikang, HU Jiabing. DFIG wind power generation systems during unbalanced network fault: analysis and operation// Proceedings of the llth International Conference on Electrical Machines and Systems, October 17-20, 2008, Wuhan, China: 2331-2336.
  • 10PETERSSON A. Analysis modeling and control of doubly-fed induction generators for wind turbines[ D]. Goteborg, Sweden:Chalmers University of Technology, 2005.

共引文献53

同被引文献116

引证文献14

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部