期刊文献+

气液两相流液相体积含量的精确测量 被引量:1

Accurate Measurement of Liquid Phase Volumetric Fraction in Gas/Liquid Two phase Flow
在线阅读 下载PDF
导出
摘要 两相流多变的流型导致电容传感器测量组分体积含量时精度较低。仿真试验结果显示,管道气—油两相流含油率的测量误差高达15% 以上。利用层析成象电容传感器阵列获取的管道内部两相流分布情况的投影值,可确定对组分体积含量的修正方法,使误差显著降低。本文分析了流型对测量的影响,导出了修正公式,介绍两种修正方法及仿真修正结果。 Flow regimes have great influences on measurement of volumetric fraction of two phase flows by capacitance transducers.The error percentage will be over 15% to measure oil fraction of gas/oil two phase flow in a pipeline by simulation tests.A correction method can be used to reduce the error significantly by use of the projections from the tomographic capacitance transducer array.In this paper the influences of flow regimes are analyzed and a correction formula is derived.Two kinds of usage are introduced and verified by typical regimes.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 1999年第6期641-643,共3页 Chinese Journal of Scientific Instrument
基金 国家重点科技项目
关键词 体积含量 修正 两相流 误差 层析成象 电容传感器 Volumetric fraction Correction Two phase flow Errors Tomography Capacitance transducer
  • 相关文献

参考文献3

  • 1Xie C G,IEEE Proc G,1992年,139卷,1期,89页
  • 2陈季丹,电介质物理学,1982年
  • 3冯慈璋,电磁场.电工原理,1979年

同被引文献5

  • 1庄海军,刘兴斌,梅艳.一种测量油井产液含水率的电容式传感器[J].传感器技术,1997,16(2):39-41. 被引量:8
  • 2Xie C G, Huang S M. Hoyle B S, et al. Electrical capacitance tomography for flow imaging: system model for development of image reconstruction algorithms and design of primary sensors[J]. IEE Proceedings-G. 1992,139(1) : 89-98.
  • 3Diclin F J, Beck M S. Tomographic imaging of industrial process equipment: techniques and applications[J]. IEE proceeding-G, 1992, 139(1): 72-82.
  • 4Liu S, Fu L, Yang W Q, et al. Prior iteration for image reconstruction with electrical capacitance tomography[J].IEE Proc. Sci. Meas. Technol., 2004, 151(3): 195-200.
  • 5刘石,许华,王海刚,姜凡,杨五强.迭代法ECT对循环流化床底部固体浓度的测量[J].工程热物理学报,2002,23(6):757-760. 被引量:2