通过分段冷却试验,并对试验结果进行了回归分析,得到了消除16Mn钢板铁素体—珠光体带状组织的临界冷却速度的计算公式,并与文献数值进行了对比,提出了改进计算精度的方法。
Stepped cooling tests ware carried out to the samples,the critical cooling rate above which the banded structure of ferrite perlite in 16 Mn steel plate could disappear were obtained by regression analysis of the test results,and compared with the document values.An approach to improve calculation precision was proposed.
出处
《上海金属》
CAS
1999年第6期25-28,共4页
Shanghai Metals
关键词
钢板
带状组织
临界冷却速度
热轧