期刊文献+

SPECT心肌灌注断层显像左心室的自动提取 被引量:6

Automatic extration of left ventrical in SPECT myocardal perfusion imaging
暂未订购
导出
摘要 通过分析SPECT心肌灌注断层图象的象素点之几何分布,利用最小二乘法拟合心肌左心室的半球加圆柱模型,采用迭代算法去除非左心室组织显影,实现左心室的自动提取。该技术为进一步定量分析提供了基础。 An automatic method of extracting left ventricle from SPECT myocardialperfusion data was introduced. This method was based on the least square analysis ofthe positions of all short-axis slices pixels from the half sphere-cylinder myocardialmodel, and used a iterative reconstrution technique to automatically cut off thenon-left rentricular tissue from the perfusion images. Thereby, this techniqueprovided the bases for further quantitative analysis.
出处 《核技术》 CAS CSCD 北大核心 1999年第11期668-673,共6页 Nuclear Techniques
基金 国家攀登计划!85-45-03-3
关键词 SPECT 心肌显像 冠心病 定性分析 诊断 SPECT Myocardium tomography 3D imaging segmentating Iterativereconstraction
  • 相关文献

参考文献3

  • 1赵书俊 刘力 等.-[J].国外医学--放射医学核医学分册,1998,22:108-112.
  • 2赵书俊,国外医学.放射医学核医学分册,1998年,22卷,108页
  • 3Germano G,J Nucl Med,1995年,36卷,1107页

同被引文献24

  • 1周颖,何青,屈婉莹,高文萍,朱明,赵洪山,周清华,高天科.^(99m)Tc-MIBI门控心肌断层显像同时评价心肌灌注和左室功能[J].中华核医学杂志,1995,15(2):87-89. 被引量:20
  • 21,Miles KA, How does gated SPET alter reporting of myocardial perfusion studies?, Nucl Med Commu, 1997,18:915~921.
  • 32,DePuey EG, Rozanski A, Gated technetium-99m sestamibi SPECT to characterise fixed myocardial defects as infarct or artifact. J Nucl Med, 1995,36:952~955.
  • 43,Williams KA, and Taillon LA, Left ventricular fraction in patients with coronary artery disease assessed by ga-ted tomographic myocardial perfusion images. J Am Coll Cardiol, 1996, 27:173~181.
  • 54,Mochizuki T, Murase K, Tanaka H, et al., Assessment of Left ventricular volume using ECG gated SPECT with technetium-99m-MIBI and technetium-99m-tetrofosmin. J Nucl Med, 1997, 38:53~57.
  • 6Lancaster JL,Starling MR,Kopp DT,et al.Effect of errors in reangulation on planar and tomographie thanium-201 washout profile curves.J Nucl Med ,1985,26:1445-1455.
  • 7DePuey EG,Garcia EV.Optimal specificity of thaUium-201 SPECT through recognition of imaging artifacts.J Nucl Med,1989,30:441-449.
  • 8DePuey EG,Garcia EV.Updated imaging guidelines for nuclear cardiology procedures,Part 1.Journal of Nuclear Cardiology,2001,8 (1):GS-G58.
  • 9Germano G,Kavanagh PB,Su HT,et al.Automatic reorientation of three-dimensional tnmsaxial myocardial perfusion SPECT images.J Nucl Med,1995,36:1107-1114.
  • 10Roberto S,Alessio I,David A,et al.Relationship of infarct size and severity versus left ventrieular ejection fraction and volumes obtained from 99mTc-sestamibi gated SPECT in patients treated with primary percutaneous coronary intervention.J Nucl Med Mol Imaging,2004;31:969

引证文献6

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部