期刊文献+

基于模型识别的小电流接地选线方法

Method of Low Current Grounding Wire Selection Based on Model Identification
在线阅读 下载PDF
导出
摘要 煤矿6 kV~10 kV电网中发生单相接地故障时,其消弧线圈的补偿作用使得故障信号变得很微弱,给故障选线技术带来很大困难。提出一种采用模式识别的小电流接地选线方法,即对每条线路分别建立故障数学模型,各条线路同时利用采集的电流电压数据求最小二乘意义下模型方程的解,依据得到的线路对地电容判断实际发生故障是否符合所建立的模型,进一步识别出故障线路。现场记录的数据验证了该方法的正确、可靠性。 The single-phase grounding fault happens in the 6 kV ~ 10 kV coal mine power system,the compensation effect of arc-suppression coil makes the fault signal weak,which is brought a great deal of difficult to fault wire selection.The low current grounding wire selection method with recognition pattern is being raised.This method sets up fault mathematic model for each wire.The result of model equation within least squares is get from the collect data of current and voltage of each wire simultaneously,according to the result of selected wires to judge the actual failure whether meets the set-up model or not,then distinguish the fault wire.The data of record on spot testified the correctness and reliability of this method.
作者 王萍
机构地区 华北煤炭医学院
出处 《煤矿机电》 2011年第2期41-43,46,共4页 Colliery Mechanical & Electrical Technology
关键词 单项接地故障 模式识别 漏电保护 single-phase grounding fault pattern recognition leakage protection
  • 相关文献

参考文献6

二级参考文献10

  • 1华北电业管理局.电力工程电工手册第二分册[M].北京:水力电力出版社,1991..
  • 2张传利.变压器微机保护的研究:学位论文[M].北京:清华大学电机系,1998..
  • 3葛耀中 周立求 等.小接地电流系统接地故障选线方法的研究[J].电力系统自动化,1985,9(3).
  • 4南京工学院数学教研组.积分变换(第三版)[M].北京:高等教育出版社,1989..
  • 5张启辉 蒋吴.模糊控制原理与应用[M].北京:电子工业出版社,2001..
  • 6北京邮电学院通信教研室.数据通信及传输原理[M].北京:人民邮电出版社,2002..
  • 7顾永辉 范廷瓒.煤矿电工手册[M].北京:煤炭工业出版社,1994..
  • 8煤炭工业部.三大保护整定细则[M].北京:煤炭工业出版社,1998..
  • 9曾祥君,尹项根,张哲,陈德树.配电网接地故障负序电流分布及接地保护原理研究[J].中国电机工程学报,2001,21(6):84-89. 被引量:151
  • 10胡天禄.零序电压随r,C,R变化的规律[J].中国矿业大学学报,2002,31(3):306-309. 被引量:5