1Faddis MN, Blume W, Finney J, et al. Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation[J] Circulation, 2002,106(23) :2980-2985.
2Ernst S, Ouyang F, Linder C, et al. Initial experience with remote catheter ablation using a novel magnetic navigation system: magnetic remote catheter ablation[J] Circulation, 2004, 109(12) : 1472-1475.
3Chun JK, Ernst S, Matthews S, et al. Remote-controlled catheter ablation of accessory pathways: results from the magnetic laboratory[J]. Eur Heart J, 2007,28(2):190-195.
4Wood MA, Orlov M, Ramaswamy K, et al. Remote magnetic manual catheter navigation for ablation of supraventricular tachycardias: a randomized, multicenter trial[J].acing Clin Electrophysiol, 2008,31 (10) : 1313-1321.
5Pappone C, Vicedomini G, Manguso F, et al. Robotic magnetic navigation for atrial fibrillation ablation [J]. Am Coil Cardiol, 2006,47(7) : 1390-1400.
6Di Biase L, Fahmy TS, Patel D, et al. Remote magnetic navigation: human experience in pulmonary vein ablation[J]. Am Coll Cardiol, 2007,50(9) :868 874.
7Chun KR, Wissner E, Koektuerk B, et al. Remote-controlled magnetic pulmonary vein isolation using a new irrigated-tip catheter in patients with atrial fibrillation[J].irc Arrhythm Electrophysiol, 2010,3(5) :458 464.
8Arya A, Kottkamp H, Piorkowski C, et al. Initial clinical experience with a remote magnetic catheter navigation system for ablation of cavotricuspid isthmus dependent right atrial flutter[J]. Pacing Clin Electrophysiol, 2008,31 (5) : 597-603.
9Huo Y, Hindricks G, Piorkowski C, et al. Six month followup of isthmus-dependent right atrial flutter ablation using a remote magnetic catheter navigation system= a case-control study[J].cta Cardiol, 2010,65(3) :279-283.
10Vollmann D, Luthje L, Seegers J, et al. Remote magnetic catheter navigation for cavotricuspid isthmus ablation in patients with common-type atrial flutter[J] Circ Arrhythm Electrophysiol, 2009,2(6) :603 -610.
3Thornton AS,Rivem Ayerza M,Knops P,et al.Magnetic navigation in left-sidedAV reentrant tachycardlas:preliminary results of a retorgrade approach[J].J Interv Cardiol,2007,18(5):467-472.
4Schneider M A,Hoch FV,Neuser H,et al.Magnetic-guided percutaneous coronary intervention enabled by two-dimensional guidewire steering and three-dimensional virtual angioscopy:initial experiences in daily clinical practice[J].J Interv Cardiol,2008,21(2):158-166.
5Szili-Torok T,Schwagten B,Akca F,et al.Catheter ablation of ventricular tachycardias using remote magnetic navigation:a consecutive case-control study[J].Cardiovasc Electrophysiol,2012,23(9):948-954.
6Emst S,Ouyang F,Linder C,et al.Initial experience with remote catheter ablation using a novel magnetic navigation system:magnetic remote catheter ablation[J].Circulation,2004,109(12):1472-1475.
8Jilek C,Tzeis S,Reents T,et al.Safety of implantable pacemakers and cardioverter defibrillators in the magnetic field of a novel remote magnetic navigation system[J].J Cardiovasc Electrophysiol,2010,21(10):1136-1141.
9Mischke K,Knackstedt C,Schmid M,et al.Initial experience with remote magnetic navigation for left ventricular lead placement[J].Acta Cardiol,2009,64(4):467-475.
10Akca F,Bauernfeind T,Witsenburg M,et al.Acute and long-term outcomes of catheter ablation using remote magnetic navigation in patients with congenital heart disease[J].Am J Cardiol,2012,110(3):409-414.